Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEWMAN TECHNOLOGY OF ALABAMA, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NEWMAN TECHNOLOGY OF ALABAMA, INC. in 2331 GEORGE WALLACE DRIVE, ALBERTVILLE, AL 35951 (NAICS 336399). OSHA activity number 343022513.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Newman Technology of Alabama, INC. — free Get an email when a new federal OSHA severe-injury report for Newman Technology of Alabama, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2331 GEORGE WALLACE DRIVE
City
ALBERTVILLE
State
AL
ZIP
35951
Mailing
2331 GEORGE WALLACE DRIVE, ALBERTVILLE, AL 35951
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
330
Ownership type
A

5 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 3 instances 70 exposed
Issued
Jul 17, 2018
Abate by
Aug 17, 2018
Penalty
Initial $6,282 · Current $3,769 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained, so far as possible, in a dry condition.  Drainage was not maintained where wet process(es) were in use:  a) On or about 3/16/18 - Line 1 Inline weld and leak test are, water from the exhaust test dip tank had accumulated on the floor in the walking and working areas.  b) On or about 3/16/18 - Line 2 Inline weld and leak test area, water from the exhaust test dip tank had accumulated on the floor in the walking and working areas.  c) On or about 3/16/18 - Line 3 Inline weld and leak test area, water from the exhaust test dip tank had accumulated on the floor in the walking and working areas.
Recent events (2)
  • — I (S) $3769.2
  • — Z (S) $6282

1910.132 A

Serious Gravity 1 2 instances 70 exposed
Issued
Jul 17, 2018
Abate by
Aug 31, 2018
Penalty
Initial $4,712 · Current $2,827 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  a) On or about 3/16/18 - Exhaust Department, the welders assigned to in-line and off-line welding stations were not provided and did not utilize welding apron or welding jacket to protect the upper torso.
Recent events (2)
  • — I (S) $2827.2
  • — Z (S) $4712

1910.132 C

Serious Gravity 1 2 instances 70 exposed
Issued
Jul 17, 2018
Abate by
Aug 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed:  a) On or about 3/16/18 - Exhaust Department, the welders assigned to in-line and off-line welding stations were exposed to contact with sparks and hot surfaces when welding. The short cuff of the knit glove used during welding, did not provide protection to the wrist and forearms.   b) On or about 3/16/18 - Exhaust Department, the robot welder operators were exposed to contact with hot surfaces when removing parts. The short cuff of the Kevlar knit glove did not provide protection to the wrist and forearms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Other-than-serious 1 instance 60 exposed
Issued
Jul 17, 2018
Abate by
Jul 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  a) On or about 3/16/18 - Exhaust Department, the employer had not obtained a current Safety Data Sheet ( SDS) for the stainless steel and stainless steel welding wire used in the welding processes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 60 exposed
Issued
Jul 17, 2018
Abate by
Aug 10, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) On or about 3/16/18 - Facility, Exhaust Department, the employer had not trained employees on the hazards associated with exposures to hexavalent chromium.  The training should include potential exposures during work processes and the engineering and work practices that should be used to control exposures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Newman Technology of Alabama, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343022513.