Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OHIO GRATINGS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OHIO GRATINGS INC. in 5299 SOUTHWAY ST. SW., CANTON, OH 44706 (NAICS 332323). OSHA activity number 343024253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ohio Gratings INC. — free Get an email when a new federal OSHA severe-injury report for Ohio Gratings INC. is published. One employer, no account, unsubscribe in one click.
Establishment
OHIO GRATINGS INC.
Site address
5299 SOUTHWAY ST. SW.
City
CANTON
State
OH
ZIP
44706
Mailing
5299 SOUTHWAY ST. SW., CANTON, OH 44706
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
400
Ownership type
A

4 citations on file for this inspection.

1910.147 C07 I A

Other-than-serious 1 instance 1 exposed
Issued
Jun 18, 2018
Abate by
Jul 13, 2018
Penalty
Initial $8,315 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    On or about March 12, 2018, the employer did not ensure press operators authorized to perform service and maintenance activities, such as die changes (setup), on the Bliss C-75 mechanical power press, known as press EP10 Connecting Bar Press, received training in the recognition of hazardous energy sources, the type and magnitude of the energy available, and the methods and means necessary for energy isolation and control of the press.
Recent events (3)
  • — F (O) $0
  • — C (S) $8315
  • — Z (S) $8315

1910.217 B07 IX

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 18, 2018
Penalty
Initial $8,315 · Current $8,315
29 CFR 1910.217(b)(7)(ix): If foot control is provided, the selection method between hand and foot control shall be separate from the stroking selector and shall be designed so that the selection may be supervised by the employer.     On or about March 12, 2018, the employer did not ensure the selection between foot control operation and two hand control operation of a Bliss C-75 mechanical power press, known as the EP10 connecting bar press, was supervised.  The key was left in the press control panel selector switch and used by press operators without employer supervision.
Recent events (3)
  • — F (S) $8315
  • — C (S) $8315
  • — Z (S) $8315

1910.217 C01 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 18, 2018
Penalty
Initial $11,641 · Current $0 Reduced
29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10.   On or about March 12, 2018, the employer did not insure fixed barrier type point of operation guards were properly applied and adjusted per 1910.217 Table O-10 to prevent the hands and/or fingers of the operator of a Bliss C-75 mechanical power press, known as the EP10 Connecting Bar Press, from entering into the point of operation.
Recent events (3)
  • — F (S) $0
  • — C (S) $11641
  • — Z (S) $11641

1910.217 C02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 18, 2018
Penalty
Initial $11,641 · Current $11,641
29 CFR 1910.217(c)(2)(iii): A fixed barrier guard shall be attached securely to the frame of the press or to the bolster plate.     On or about March 12, 2018, the employer did not ensure a fixed barrier type guard used to protect the point of operation of a Bliss C-75 mechanical power press, known as the EP10 connecting bar press, was securely attached to the frame and/or bolster plate of the press.
Recent events (3)
  • — F (S) $11641
  • — C (S) $11641
  • — Z (S) $11641

View Ohio Gratings INC.'s full OSHA safety record →