MOUNT VERNON, OH —
OSHA Inspection: AMG INDUSTRIES, LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AMG INDUSTRIES, LLC. in 200 COMMERCE DRIVE, MOUNT VERNON, OH 43050 (NAICS 336370). OSHA activity number 343035374.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMG INDUSTRIES, LLC.
- Site address
- 200 COMMERCE DRIVE
- City
- MOUNT VERNON
- State
- OH
- ZIP
- 43050
- Mailing
- 200 COMMERCE DRIVE, MOUNT VERNON, OH 43050
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 145
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.217 B07 II
- Issued
- Jul 24, 2018
- Abate by
- Aug 13, 2018
- Penalty
- Initial $4,664 · Current $2,798 Reduced
General-duty citation text
29 CFR 1910.217(b)(7)(ii): A red color stop control shall be provided with the clutch/brake control system. Momentary operation of the stop control shall immediately deactivate the clutch and apply the brake. The stop control shall override any other control, and reactuation of the clutch shall require use of the operating (tripping) means which has been selected. a. On or about March 22, 2018, in plant 1, department 1000, the emergency stop button for the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) was not red in color.
Recent events (2)
- — I (S) $2798.4
- — Z (S) $4664
1910.217 B07 V A
- Issued
- Jul 24, 2018
- Abate by
- Aug 13, 2018
- Penalty
- Initial $7,775 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(b)(7)(v)(a): Each hand control shall be protected against unintended operation and arranged by design, construction, and/or separation so that the concurrent use of both hands is required to trip the press. a. On or about March 22, 2018, in plant 1, department 1000, the two hand control buttons for the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) were not protected against unintended operation with a device such as ring guards.
Recent events (2)
- — I (S) $0
- — Z (S) $7775
1910.217 C01 I
- Issued
- Jul 24, 2018
- Abate by
- Aug 13, 2018
- Penalty
- Initial $7,775 · Current $4,665 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10. a. On or about March 22, 2018, in plant 1, department 1000, the point of operation at the exit end of the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) was not guarded.
Recent events (2)
- — I (S) $4665
- — Z (S) $7775
1910.305 B01 II
- Issued
- Jul 24, 2018
- Penalty
- Initial $4,664 · Current $2,798 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a. On or about March 22, 2018, in plant 1, department 1000, the two hand control station/stand for the 200 ton Bliss press 312 (model: SC2-200; S/N: H-71352) had an unused opening due to a missing knockout, thereby exposing employees to an electrical contact hazard.
Recent events (2)
- — I (O) $2798.4
- — Z (S) $4664
1910.305 F01
- Issued
- Jul 24, 2018
- Penalty
- Initial $4,664 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(f)(1): Insulation. All conductors used for general wiring shall be insulated unless otherwise permitted in this subpart. a. On or about March 22, 2018, in plant 1, department 1000, the outer insulation/sheath on the flexible cord for the conveyor motor at the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) was damaged, thereby exposing employees to an electrical contact hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $4664
1910.305 G02 II
- Issued
- Jul 24, 2018
- Penalty
- Initial $7,775 · Current $4,665 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. a. On or about March 22, 2018, in plant 1, department 1000, the flexible cord for the conveyor motor at the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) was spliced and wrapped with tape, thereby exposing employees to an electrical contact hazard.
Recent events (2)
- — I (S) $4665
- — Z (S) $7775
1910.1200 F06 II
- Issued
- Jul 24, 2018
- Abate by
- Aug 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either: 29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a. On or about March 22, 2018, in plant 1, department 1000, a spray bottle containing Renoform OS 7806 at the 100 ton Federal press 301 (model: S2-100-48-42; S/N: S2-217) was not labeled. b. On or about March 22, 2018, in plant 1, department 1000, a spray bottle containing Renoform OS 7806 at the 200 ton Bliss press 312 (model: SC2-200; S/N: H-71352) was not labeled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AMG Industries, LLC.
View AMG Industries, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343035374.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.