DAYTON, OH —
OSHA Inspection: MANCOR OHIO INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MANCOR OHIO INC. in 1008 LEONHARD STREET, DAYTON, OH 45404 (NAICS 336112). OSHA activity number 343037081.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANCOR OHIO INC.
- Site address
- 1008 LEONHARD STREET
- City
- DAYTON
- State
- OH
- ZIP
- 45404
- Mailing
- 1008 LEONHARD STREET, DAYTON, OH 45404
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336112
- Employees
- 99
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.217 B13
- Issued
- Jul 23, 2018
- Abate by
- Sep 7, 2018
- Penalty
- Initial $11,641 · Current $6,985 Reduced
General-duty citation text
29 CFR 1910.217(b)(13): Control reliability. When required by paragraph (c)(5) of this section, the control system shall be constructed so that a failure within the system does not prevent the normal stopping action from being applied to the press when required, but does prevent initiation of a successive stroke until the failure is corrected. The failure shall be detectable by a simple test, or indicated by the control system. This requirement does not apply to those elements of the control system which have no effect on the protection against point of operation injuries. On March 16, 2018, in the Production Area on a 65 Ton Minster Part Revolution Mechanical Power Press, the control system did not detect a failure to prevent a successive stroke until the failure was detected after the press cycled and a press operator's left hand was caught between the upper and lower die while putting a metal part onto the second stage of the two stage die.
Recent events (3)
- — F (S) $6984.6
- — C (S) $11641
- — Z (S) $11641
1910.217 C05 I
- Issued
- Jul 23, 2018
- Abate by
- Sep 7, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(5)(i): The employer shall use a control system and a brake monitor which comply with paragraphs (b)(13) and (14) of this section; On March 16, 2018, in the Production Area at the Floors Department, Cell Area, the control system and brake monitor on the 65 Ton Minster Part Revolution Mechanical Power Press, M179, did not comply with paragraphs (b) (13) and (14) of this section.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Mancor Ohio INC.
View Mancor Ohio INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336112)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343037081.