BELLEVILLE, IL —
OSHA Inspection: BELTLINE BOWL, INC. DBA BEL-AIR BOWL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BELTLINE BOWL, INC. DBA BEL-AIR BOWL in 200 S BELT W, BELLEVILLE, IL 62220 (NAICS 713950). OSHA activity number 343069035.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELTLINE BOWL, INC. DBA BEL-AIR BOWL
- Site address
- 200 S BELT W
- City
- BELLEVILLE
- State
- IL
- ZIP
- 62220
- Mailing
- 200 S BELT W, BELLEVILLE, IL 62220
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713950
- Employees
- 43
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Oct 5, 2018
- Abate by
- Nov 26, 2018
- Penalty
- Initial $5,174 · Current $3,363 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: The employer did not establish a lockout/tagout program that included employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on the AMF 82-70 Pin-Setting machines, where the unexpected energizing, startup or release of store energy could occur and cause injury, the machines were isolated from all energy courses and rendered inoperative.
Recent events (2)
- — I (S) $3363
- — Z (S) $5174
1910.147 D
- Issued
- Oct 5, 2018
- Abate by
- Nov 26, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): The employer failed to implement appropriate energy control application steps for the pinsetter machine, as the gravitational energy of the machine was not isolated prior to employees performing maintenance tasks underneath the pinsetter table (per the 1910.147(d)(2) requirements). As a result the remaining applicable energy control elements, involving machine isolation [(d)(3)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Oct 5, 2018
- Abate by
- Nov 26, 2018
- Penalty
- Initial $6,467 · Current $4,204 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: The employer did not ensure that employees utilizing concentrated corrosive chemicals, such as but not limited to, Defense C, were provided with a suitable eye wash station in the work area.
Recent events (2)
- — I (S) $4204
- — Z (S) $6467
1910.1200 G08
- Issued
- Oct 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): The employer did not ensure that copies of Safety Data Sheets for hazardous chemicals used in the workplace, to include but not limited to, Simple Green Extreme Parts Cleaner, were readily available to employees during their work shift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 713950)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343069035.