Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELTLINE BOWL, INC. DBA BEL-AIR BOWL

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BELTLINE BOWL, INC. DBA BEL-AIR BOWL in 200 S BELT W, BELLEVILLE, IL 62220 (NAICS 713950). OSHA activity number 343069035.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beltline Bowl, INC. DBA Bel-Air Bowl — free Get an email when a new federal OSHA severe-injury report for Beltline Bowl, INC. DBA Bel-Air Bowl is published. One employer, no account, unsubscribe in one click.
Site address
200 S BELT W
City
BELLEVILLE
State
IL
ZIP
62220
Mailing
200 S BELT W, BELLEVILLE, IL 62220
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713950
Employees
43
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 5, 2018
Abate by
Nov 26, 2018
Penalty
Initial $5,174 · Current $3,363 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    The employer did not establish a lockout/tagout program that included employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on the AMF 82-70 Pin-Setting machines, where the unexpected energizing, startup or release of store energy could occur and cause injury, the machines were isolated from all energy courses and rendered inoperative.
Recent events (2)
  • — I (S) $3363
  • — Z (S) $5174

1910.147 D

Serious Gravity 5 20 instances 2 exposed
Issued
Oct 5, 2018
Abate by
Nov 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):    The employer failed to implement appropriate energy control application steps for the pinsetter machine, as the gravitational energy of the machine was not isolated prior to employees performing maintenance tasks underneath the pinsetter table (per the 1910.147(d)(2) requirements).  As a result the remaining applicable energy control elements, involving machine isolation [(d)(3)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 5, 2018
Abate by
Nov 26, 2018
Penalty
Initial $6,467 · Current $4,204 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    The employer did not ensure that employees utilizing concentrated corrosive chemicals, such as but not limited to, Defense C, were provided with a suitable eye wash station in the work area.
Recent events (2)
  • — I (S) $4204
  • — Z (S) $6467

1910.1200 G08

Other-than-serious 1 instance 4 exposed
Issued
Oct 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  The employer did not ensure that copies of Safety Data Sheets for hazardous chemicals used in the workplace, to include but not limited to, Simple Green Extreme Parts Cleaner, were readily available to employees during their work shift.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343069035.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.