Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JONATHAN A. ARRIOLA DBA JAA CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JONATHAN A. ARRIOLA DBA JAA CONSTRUCTION in ENSILE DRIVE LOT 97, VERNON HILLS, IL 60061 (NAICS 238160). OSHA activity number 343081808.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jonathan a. Arriola DBA JAA Construction — free Get an email when a new federal OSHA severe-injury report for Jonathan a. Arriola DBA JAA Construction is published. One employer, no account, unsubscribe in one click.
Site address
ENSILE DRIVE LOT 97
City
VERNON HILLS
State
IL
ZIP
60061
Mailing
36782 N. WILDWOOD DRIVE, LAKE VILLA, IL 60046
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 25, 2018
Abate by
Jul 31, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:      Jonathan A. Arriola dba JAA Construction failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:        Citation Number         Item Number                 Abatement Date   01                                01                                   04/20/2018   01                                02a                                 04/20/2018   01                                02b                                 04/20/2018   01                                03                                   04/20/2018   01                                04                                   04/20/2018   01                                05                                   04/20/2018   01                                06                                   04/20/2018  02                                01                                   05/10/2018  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $311

1926.451 E01

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:         a) On or about April 12, 2018, employees were exposed to fall hazards while climbing to and from a ladder jack scaffold platform without safe access at an elevation of approximately 21 feet.  b) On or about April 12, 2018, employees were exposed to fall hazards while climbing to and from a ladder jack scaffold platform without safe access at an elevation of approximately 25 feet.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3880

1926.451 G01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:         a) On or about April 12, 2018, employees were exposed to the hazard of falling between 21 and 25 feet while working from ladder jack scaffolding without the benefit of fall protection.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $3880

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):          a) On or about April 12, 2018, employees were exposed to the hazard of falling while performing roofing work without fall protection from pitched roof surfaces having a ground to eave height of approximately 25 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.452 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.452(k)(1): Ladder jack scaffold platforms exceeded a height of 20 feet (6.1 m):           a) On or about April 12, 2018, employees were exposed to the hazard of falling between approximately 21 and 25 feet during the performance of work from a ladder jack scaffold that exceeded the 20 foot maximum permissible height for ladder jack scaffolding.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2772

1926.452 K05

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $2,772 · Current $2,772
CFR 1926.452(k)(5): Scaffold platforms were bridged on to another:       a) On or about April 12, 2018, employees were exposed to the hazard of falling between 21 and 25 feet where scaffold platforms were bridged together.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2772

1926.502 D15

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person:     a) On or about April 12, 2018, a fall protection anchorage device designed to support 5,000 pounds per one employee was being used to support two employees simultaneously during roofing work while the single anchor was only partially attached to the ridge of the roofline.  b) On or about April 12, 2018, an anchor used by a single employee as part of a fall protection system was not connected completely to ensure the device would be capable of supporting at least 5,000 pounds of force.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2772

1926.1053 B16

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 16, 2018
Abate by
Apr 20, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:      a) On or about April 12, 2018, a portable extension ladder provided for use had a broken rung.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $1663

1926.503 B01

Other-than-serious 3 instances 3 exposed
Issued
Apr 16, 2018
Abate by
May 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:      a) On or about April 12, 2018, the employer did not prepare written certification records related to employee fall protection training      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $0

View Jonathan a. Arriola DBA JAA Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343081808.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.