Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLEARSPAN COMPONENTS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CLEARSPAN COMPONENTS, INC. in 6110 OLD HWY 80 W, MERIDIAN, MS 39301 (NAICS 321918). OSHA activity number 343091823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clearspan Components, INC. — free Get an email when a new federal OSHA severe-injury report for Clearspan Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6110 OLD HWY 80 W
City
MERIDIAN
State
MS
ZIP
39301
Mailing
P.O. BOX 4195, MERIDIAN, MS 39304
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
35
Ownership type
A

9 citations on file for this inspection.

1910.25 B03

Serious Gravity 1 1 instance 20 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $3,880 · Current $2,700 Reduced
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings:    (a)  Mechanic Shop - On or about April 19, 2018 the stairs did not have risers that were uniform.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3880

1910.28 B03 II

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $3,880 · Current $2,700 Reduced
29 CFR 1910.28(b)(3)(ii): (ii) Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems;    (a)  Exterior Wall Line  - On or about April 19, 2018 an opening in the floor approximately 12 inches wide and 17 inches deep was not guarded against employees stepping into the opening.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3880

1910.147 C04 II

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $12,934 · Current $9,200 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    (a)  Facility - On or about April 17, 2018 the employer did not have specific maintenance procedures for the replacement of the hydraulic cylinder for the Caterpillar forklift.
Recent events (2)
  • — I (S) $9200
  • — Z (S) $12934

1910.178 M02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(m)(2): Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s)  (a) Facility - On or about April 17, 2018 an employees was exposed to crush hazard when the employee was standing under the elevated carriage and forks of the forklift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 M05 III

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $5,174 · Current $3,600 Reduced
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the load engaging means fully lowered:     (a)   Outside the Main Exterior wall building - On or about April 19, 2018 a forklift in-service was left unattended with the power on and the forks carrying a load elevated.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $5174

1910.178 L01 I

Serious Gravity 1 1 instance 10 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  (a)   Outside the Main Exterior wall building - On or about April 19, 2018 the employer did not ensure that a forklift operator had been trained.  The operator left a forklift unattended with the power on and the forks carrying a load elevated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C04 I

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $3,880 · Current $2,500 Reduced
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves.    (a)  Exterior Main Wall Line - On or about April 19, 2018 a 2 inch shaft end projected more than 2 inches.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3880

1910.219 F03

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $3,880 · Current $2,700 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    (a)  Roof Department - On or about April 19, 2018 the chain and sprocket for the scrap conveyor was not guarded.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3880

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Sep 19, 2018
Abate by
Oct 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a)  Interior Wall Line - On or about April 19, 2018 wood was stored and restricting access to the electrical panel.   (b)  Roof Department - On or about April 19, 2018 a table saw was blocking access to the electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0