Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TNT EQUIPMENT COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TNT EQUIPMENT COMPANY in 7070 STATE ROUTE 13, SOMERSET, OH 43783 (NAICS 332323). OSHA activity number 343093027.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TNT Equipment Company — free Get an email when a new federal OSHA severe-injury report for TNT Equipment Company is published. One employer, no account, unsubscribe in one click.
Site address
7070 STATE ROUTE 13
City
SOMERSET
State
OH
ZIP
43783
Mailing
7070 STATE ROUTE 13, SOMERSET, OH 43783
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
17
Ownership type
A

16 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $7,114 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.   a. On or before April 17, 2018, the employer did not document specific lockout/tagout procedures for machines or equipment such as the Hyd Mech (model: M-20A; S/N: T1008678) horizontal bandsaw to protect employees while servicing and/or performing maintenance activities in which the unexpected energization or startup of the machine or equipment, or release of stored energy, could harm employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7114

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $7,114 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a. On or before April 17, 2018, the employer did not conduct periodic lockout/tagout inspections to ensure that the energy control procedure and requirements of this standard were being followed by employees performing servicing and maintenance on machines and equipment throughout the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7114

1910.147 C07 I

Serious Gravity 5 2 instances 17 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:   a. On or before April 17, 2018, the employer failed to ensure that employees who service and/or perform maintenance activities including changing blades on the Hyd Mech (model: M-20A; S/N: T1008678) horizontal bandsaw were trained in the purpose and function of the energy control procedure and in the knowledge and skills required for the safe application, usage, and removal of the energy controls.   b. On or before April 17, 2018, the employer did not ensure that each affected employee was instructed in the purpose and use of the energy control procedure.
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.178 L01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).   a. On or before April 17, 2018, the employer did not provide employees with powered industrial truck training prior to permitting employees to operate the diesel powered lifts including, but not limited to, the following:  Toyota Forklift Truck (model: 8FDU30; S/N: 11375); JLG lift (model: G9-43A; S/N: 0160038844); and Terex Lift 5519 (S/N: 0952).
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 12, 2018
Penalty
Initial $5,691 · Current $3,415 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.   a. On or about July 11, 2018, in the cut and prep area, the employer did not ensure that the rotating chuck on the Rigid Drill Press DP15501 (S/N: AM061148779) was guarded.
Recent events (2)
  • — I (S) $3414.6
  • — Z (S) $5691

1910.215 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.   a. On or about July 11, 2018, in the cut and prep area, the abrasive wheel on the right side of the GE Cadet pedestal grinder (model: 100; S/N: 34943) had a work rest that was not adjusted closely to the wheel allowing for an opening of approximately three-eighth inch.
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.215 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)   a. On or about July 11, 2018, in the cut and prep area, the abrasive wheel on the right side of the GE Cadet pedestal grinder (model: 100; S/N: 34943) did not have an adjustable tongue guard allowing for an opening of approximately seven-eighth inch between the abrasive wheel and the peripheral member.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced

Hazardous substances X100

29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.   a.  On or about April 17, 2018, in the loading zone area, two cylinders containing oxygen were not secured to prevent them from being knocked over and damaged while in storage.
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.101 B

Serious Gravity 5 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 1900

29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.   a.  On or about April 17, 2018, in the loading zone area, two cylinders containing nitrogen were not secured to prevent them from being knocked over and damaged while in storage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 III

Serious Gravity 5 1 instance 9 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.   a.  On or about April 17, 2018, in the welding area, the taped electrode cable for the Miller Millermatic 350 (S/N: LK220034N) welder used for gas metal arc welding (GMAW) had damaged insulation exposing the bare conductor.
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.303 B01 IV

Serious Gravity 5 3 instances 17 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $7,114 · Current $4,268 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:    29 CFR 1910.303(b)(1)(iv): Electrical insulation.    a. On or about April 17, 2018, in the welding area, the outer protective insulation, which was covered with electrical tape, on the cord for the DeWalt Angle Grinder (model: DWE402N) was damaged.     b. On or about April 17, 2018, in the welding area, the outer protective insulation, which was covered with electrical tape in one location, on the extension cord used to power the DeWalt Angle Grinder (model: DWE402N) was damaged in a couple of locations and had an exposed bare conductor.     c. On or about April 17, 2018, in the office, the outer protective insulation on the cord for the Bissell Vacuum Cleaner (model: 92L3-W) was damaged in a couple of locations.
Recent events (2)
  • — I (S) $4268.4
  • — Z (S) $7114

1910.304 G05

Serious Gravity 5 3 instances 17 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $7,114 · Current $0 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.     a. On or about April 17, 2018, in the welding area, the plug end of the cord for a pedestal fan (model: SFSC1-750S) was missing the ground prong.     b. On or about April 17, 2018, in the welding area, the plug end of the extension cord used to power a speaker and portable grinder was missing the ground prong.     c. On or about April 17, 2018, in the welding area, the plug end of the cord for a portable work table was missing the ground prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7114

1904.40 A

Deleted Other-than-serious 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Sep 24, 2018
Penalty
Initial $1,423 · Current $0 Reduced
29 CFR 1904.40(a): Basic requirement. When an authorized government representative asks for the records you keep under Part 1904, you must provide copies of the records within four (4) business hours.   a. On or about April 17, 2018, the employer never provided the requested OSHA Form 300 Log of Work Related Injuries and Illnesses and OSHA Form 300A Summary of Work Related Injuries and Illnesses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1423

1910.134 C02 I

Other-than-serious 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard");  a. On or before April 17, 2018, the employer did not provide respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard") where the employer determined that voluntary respirator use, such as the 3M 8210 filtering facepiece N95 respirators (dust masks) and 3M tightfitting half facepiece respirators, were permissible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 17 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).   a. On or before April 17, 2018, the employer did not establish and implement those elements of a written respiratory protection program necessary to ensure that any employees voluntarily using a respirator, such as the 3M tightfitting half facepiece respirators, were medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 5 exposed
Issued
Sep 12, 2018
Abate by
Oct 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.   a. On or before April 17, 2018, the employer did not provide hazard communication training for employees exposed to hazardous chemicals such as, but not limited to, the following: Radnor anti-splatter spray, WD-40, PB Blaster, argon/carbon dioxide gas, acetylene, oxygen, metal fumes, grease, bleach, Fabuloso cleaner, 409 cleaner, cutting fluid, and diesel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TNT Equipment Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343093027.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.