UTICA, NY —
OSHA Inspection: CONMED CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONMED CORPORATION in 525 FRENCH ROAD, UTICA, NY 13502 (NAICS 334510). OSHA activity number 343094330.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONMED CORPORATION
- Site address
- 525 FRENCH ROAD
- City
- UTICA
- State
- NY
- ZIP
- 13502
- Mailing
- 525 FRENCH ROAD, UTICA, NY 13502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334510
- Employees
- 865
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- May 29, 2018
- Penalty
- Initial $5,544 · Current $3,603 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the below-the-hook lifting devices fail: a) Electrode Factory, Wolverine Oven, Chain Hoist #2, on or about 4/18/18: A below-the-hook lifting device (hoist bar) attached to a Budgit 1/2 ton overhead hoist, had no rated load capacity markings on it and had not been inspected. b) Electrode Factory, Slitter, Chain Hoist #1, on or about 4/18/18: Two below-the-hook lifting devices (hoist bars) being used on a Budgit 1/2 ton overhead hoist, had no rated load capacity markings on them and had not been inspected.
Recent events (2)
- — I (S) $3603.3
- — Z (S) $5544
1910.157 G02
- Issued
- May 29, 2018
- Penalty
- Initial $5,544 · Current $3,603 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 5/3/18: Training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting.
Recent events (2)
- — I (S) $3603.3
- — Z (S) $5544
1910.212 A01
- Issued
- May 29, 2018
- Penalty
- Initial $9,239 · Current $6,005 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip points, rotating parts and moving parts: a) Electrode Factory, Autoline 16, on or about 4/18/18: Ingoing nip points at the nip rollers at the snap station, gel station and cutter station were not guarded. b) Electrode Factory, Autoline #7, on or about 4/18/18: Ingoing nip points at the nip rollers at two gel laminator stations were not guarded. c) Electrode Factory, Autoline #3, on or about 4/18/18: Ingoing nip points at the nip rollers near the cutter station were not guarded. d) Molding Factory, on or about 4/19/18: Moving parts on the Yankeur bender at the ejection station were not adequately guarded in that there was a four inch opening in the existing guard. e) Molding Factory, on or about 4/19/18: Moving shuttle table on a Newbury Molder #21 was not guarded. f) Molding Factory, Wire & Cable Room, on or about 4/19/18: Ingoing nip points on the pulleys feeding cable into the Artos cutter #1109 were not guarded. g) Mold Maintenance Cage, on or about 4/19/18: Rotating chuck on a Duro drill press was not guarded. h) Maintenance Shop, on or about 4/19/18: Unused portion of blade on an Enco horizontal bandsaw was not guarded on the right side. i) Maintenance Shop, on or about 4/19/18: Rotating chuck on a Powermatic drill press was not guarded. j) Machine Shop, on or about 4/19/18: Rotating chucks on a Delta drill press and an Orbit drill press were not guarded.
Recent events (2)
- — I (S) $6005.35
- — Z (S) $9239
1910.212 B
- Issued
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Mold Maintenance Cage, on or about 4/19/18: A Duro drill press was not secured to prevent walking or moving.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- May 29, 2018
- Penalty
- Initial $12,675 · Current $8,239 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Electrode Factory, Autoline 16, on or about 4/18/18: Point of operation was not guarded at cutter station #27. b) Electrode Factory, Autoline 3, on or about 4/18/18: Point of operation was not guarded at the cutter station. c) Electrode Factory, Autoline 5, on or about 4/18/18: Point of operation was not adequately guarded at the cutter station in that the guard provided did not prevent entry into the left side of the cutter. d) Electrode Factory, Crimper area, on or about 4/18/18: Point of operation was not adequately guarded on a Kenco back pad receptacle crimper #5079 and a Kenco stripper receptacle crimper #606 in that you could reach into the point operation. e) Molding Factory, Wire & Cable Room, on or about 4/19/18: Point of operation was not adequately guarded on Amp crimpers #959L, #3587 and 960L in that you could reach into the point of operation.
Recent events (2)
- — I (S) $8238.75
- — Z (S) $12675
1910.303 B02
- Issued
- May 29, 2018
- Penalty
- Initial $5,544 · Current $3,603 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Electrode Factory, Autoline 14, on or about 4/18/18: A power strip being used to power a band sealer and a date coder was not being used in accordance with the listing or labeling. b) Electrode Factory, Autoline 12, on or about 4/18/18: A power strip being used to power a band sealer and a date coder was not being used in accordance with the listing or labeling. c) Electrode Factory, Thermogard Cell, on or about 4/18/18: A power strip at the final pack area used to power a sealer and date coder was not being used in accordance with the listing or labeling. d) Electrode Factory, Thermogard Cell, on or about 4/18/18: A power strip at the Thermogard welder area used to power the welder and continuity tester was not being used in accordance with the listing or labeling. e) Molding Factory, Hyfrecator Cell, on or about 4/19/18: A power strip used to power a tube bender, scale, vibration bowl, actuator, etc. was not being used in accordance with the listing or labeling. f) Molding Factory, on or about 4/19/18: A power strip being used to power the Imtran pad printer #3589 was not being used in accordance with the listing or labeling.
Recent events (2)
- — I (S) $3603.3
- — Z (S) $5544
1910.305 G01 IV A
- Issued
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Molding Factory, Sumitamo molder #48, on or about 4/19/18: Extension cord providing current to the loader control #5205 was being used as permanent wiring.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B03 IV
- Issued
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(3)(iv): The employer did not ensure each employee was protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used: a) Mold Mix Area, on or about 4/19/18: A ladderway opening on the mold mix platform, approximately 5 1/2 feet from floor level was not provided with a self-closing gate.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Electrode Factory, Main Hall, on or about 4/18/18: Two circuit breaker panels across from Autoline #14 did not have all of the breakers labeled as to what they controlled. b) Mold Maintenance Case, on or about 4/19/18: Circuit breaker panel A did not have all of the breakers labeled as to what they controlled.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- May 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Molding Factory, on or about 4/19/18: Flexible cord on the temperature controller for the Cincinnati Molder #40 was pulled loose at the fitting.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Conmed Corporation
View Conmed Corporation's full OSHA safety record →
More inspections in this industry (NAICS 334510)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343094330.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.