Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ECM CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ECM CONSTRUCTION, LLC in 9555 W RINGLE CREEK STREET, STAR, ID 83669 (NAICS 238130). OSHA activity number 343101689.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ECM Construction, LLC — free Get an email when a new federal OSHA severe-injury report for ECM Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9555 W RINGLE CREEK STREET
City
STAR
State
ID
ZIP
83669
Mailing
104 S GREENSCAPE WAY, NAMPA, ID 83687
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 30, 2018
Abate by
May 24, 2018
Penalty
Initial $3,326 · Current $1,663 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  a) On or about April 20, 2018 and at times prior thereto employees were exposed to struck by hazards while working below other employees who were using pneumatic nail guns and hand tools, and while lifting sheets of exterior roof sheathing over their head to the above employees, where no hard hats were worn.  NOTE-Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $3326

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Apr 30, 2018
Abate by
May 24, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On or about April 20, 2018 and at times prior thereto employees were nailing exterior sheathing to a roof, exposed to fall hazards from between 13 to 19 feet, where no fall protection was provided or used.  b) On or about April 20, 2018 and at times prior thereto employees were working on the second floor exposed to 10 foot fall hazards at three unguarded wall openings, where no fall protection was provided or used.  NOTE-Abatement certification and documentation are required for this item.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1926.503 A01

Serious Gravity 1 2 instances 4 exposed
Issued
Apr 30, 2018
Abate by
May 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) On or about April 20, 2018 and at times prior thereto employees were exposed to fall hazards of 10, 13, and 19 feet to the ground below, where untrained employees were unable to recognize or avoid the hazards, or to wear and use personal fall arrest systems.  NOTE-Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 30, 2018
Abate by
May 24, 2018
Penalty
Initial $3,326 · Current $1,663 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) On or about April 20, 2018 and at times prior thereto employees were working from a 10 foot ladder which was folded, and leaning against the building.  NOTE-Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1663
  • — Z (S) $3326

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 30, 2018
Abate by
May 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) On or about April 20, 2018 and at times prior thereto employees were using the top and top step of an eight foot folding ladder to access a 10 foot high second floor.  NOTE-Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ECM Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343101689.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.