OSHA Inspection: HIGH PEAK ROOFING & PAINTING, INCORPORATED

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HIGH PEAK ROOFING & PAINTING, INCORPORATED in 123 E. GRAMBY STREET, MANHEIM, PA 17545 (NAICS 238160). OSHA activity number 343107165.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch High Peak Roofing & Painting, Incorporated — free Get an email when a new federal OSHA severe-injury report for High Peak Roofing & Painting, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
123 E. GRAMBY STREET
City
MANHEIM
State
PA
ZIP
17545
Mailing
2301 RITNER HIGHWAY, CARLISLE, PA 17015
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.502 H01 V

Serious Gravity 10 1 instance 5 exposed
Issued
May 15, 2018
Abate by
Jun 11, 2018
Penalty
Initial $3,880 · Current $2,900 Reduced
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function:    a) Upper Roof of Area C; 123 E. Gramby Street, Manheim PA - The safety monitor was observed working where a safety monitoring system was in place thereby exposing employees to an approximate 35 foot fall hazard to the ground below, on or about April 23, 2018.    Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $3880

1926.503 B01

Serious Gravity 10 1 instance 6 exposed
Issued
May 15, 2018
Abate by
Jun 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section (fall protection training) by preparing a written certification record which contained the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  a) 123 E. Gramby Street, Manheim PA - The employer did not prepare a written certification verifying that employees had been trained in hazards related to falls from elevation, on or about April 23, 2018.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Repeat Gravity 10 1 instance 6 exposed
Issued
May 15, 2018
Abate by
Jun 11, 2018
Penalty
Initial $7,760 · Current $5,800 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:    a) Main Roof; 123 E. Gramby Street, Manheim PA - Employees were observed conducting roofing operations on the main roof of the building and were exposed to an approximate 26 foot fall  hazard to the ground below, on or about April 23, 2018.    Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.    High Peak Roofing and Painting, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1234449, citation number 1, item number 1 and was affirmed as a final order on July 3, 2017, with respect to a workplace located at 150 Pitney Road, Lancaster, PA 17601.
Recent events (2)
  • — I (R) $5800
  • — Z (R) $7760

View High Peak Roofing & Painting, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343107165.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.