OSHA Inspection: VENTURE METALS, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of VENTURE METALS, LLC in 10848 LUNA ROAD, DALLAS, TX 75220 (NAICS 332999). OSHA activity number 343111407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Venture Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Venture Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VENTURE METALS, LLC
Site address
10848 LUNA ROAD
City
DALLAS
State
TX
ZIP
75220
Mailing
10848 LUNA ROAD, DALLAS, TX 75220
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332999
Employees
64
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 4 instances 4 exposed
Issued
Oct 22, 2018
Abate by
Dec 10, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  (a) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for bleeding the residual air once the air supply hose has been removed, exposing employees to amputation hazards;  (b) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out sources of pneumatic energy, exposing employees to amputation hazards;  (c) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out sources of hydraulic energy, exposing employees to amputation hazards;  (d) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out the AC power supply, exposing employees to amputation hazards.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 D04 I

Serious Gravity 10 2 instances 4 exposed
Issued
Oct 22, 2018
Abate by
Dec 10, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) On or about April 25, 2018 and at times prior thereto employees servicing and maintaining the Sweed machines in the cable shop did not lockout sources of hydraulic energy, exposing employees to amputation hazards  (b) On or about April 25, 2018 and at times prior thereto employees servicing and maintaining the Sweed machines in the cable shop did not lockout sources of pneumatic energy, exposing employees to amputation hazards.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 D05 I

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 22, 2018
Abate by
Dec 10, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy were not relieved, disconnected, restrained, and otherwise rendered safe:  (a) On or about April 25, 2018 and at times prior thereto employees maintaining and servicing Sweed machines in the cable shop did not bleeding the residual air once the air supply hose has been removed, exposing employees to amputation hazards.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 D06

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 22, 2018
Abate by
Dec 10, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  (a) On or about April 25, 2018 and at times prior thereto employees maintaining and servicing Sweed machines in the cable shop did not verify that isolation and deenergization of the Sweed machines had been accomplished, exposing employees to amputation hazards.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959