DALLAS, TX —
OSHA Inspection: VENTURE METALS, LLC
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of VENTURE METALS, LLC in 10848 LUNA ROAD, DALLAS, TX 75220 (NAICS 332999). OSHA activity number 343111407.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VENTURE METALS, LLC
- Site address
- 10848 LUNA ROAD
- City
- DALLAS
- State
- TX
- ZIP
- 75220
- Mailing
- 10848 LUNA ROAD, DALLAS, TX 75220
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 64
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Oct 22, 2018
- Abate by
- Dec 10, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for bleeding the residual air once the air supply hose has been removed, exposing employees to amputation hazards; (b) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out sources of pneumatic energy, exposing employees to amputation hazards; (c) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out sources of hydraulic energy, exposing employees to amputation hazards; (d) On or about April 25, 2018 and at times prior thereto the energy control procedures for the Sweed machines in the cable shop did not include specific procedural steps for locking out the AC power supply, exposing employees to amputation hazards.
Recent events (2)
- — C (S) $9959
- — Z (S) $9959
1910.147 D04 I
- Issued
- Oct 22, 2018
- Abate by
- Dec 10, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about April 25, 2018 and at times prior thereto employees servicing and maintaining the Sweed machines in the cable shop did not lockout sources of hydraulic energy, exposing employees to amputation hazards (b) On or about April 25, 2018 and at times prior thereto employees servicing and maintaining the Sweed machines in the cable shop did not lockout sources of pneumatic energy, exposing employees to amputation hazards.
Recent events (2)
- — C (S) $9959
- — Z (S) $9959
1910.147 D05 I
- Issued
- Oct 22, 2018
- Abate by
- Dec 10, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy were not relieved, disconnected, restrained, and otherwise rendered safe: (a) On or about April 25, 2018 and at times prior thereto employees maintaining and servicing Sweed machines in the cable shop did not bleeding the residual air once the air supply hose has been removed, exposing employees to amputation hazards.
Recent events (2)
- — C (S) $9959
- — Z (S) $9959
1910.147 D06
- Issued
- Oct 22, 2018
- Abate by
- Dec 10, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: (a) On or about April 25, 2018 and at times prior thereto employees maintaining and servicing Sweed machines in the cable shop did not verify that isolation and deenergization of the Sweed machines had been accomplished, exposing employees to amputation hazards.
Recent events (2)
- — C (S) $9959
- — Z (S) $9959
More inspections at Venture Metals, LLC
View Venture Metals, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343111407.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.