OSHA Inspection: VENTURE METALS, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of VENTURE METALS, LLC in 10848 LUNA ROAD, DALLAS, TX 75220 (NAICS 423930). OSHA activity number 343150306.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Venture Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Venture Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VENTURE METALS, LLC
Site address
10848 LUNA ROAD
City
DALLAS
State
TX
ZIP
75220
Mailing
10848 LUNA ROAD, DALLAS, TX 75220
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
423930
Employees
64
Ownership type
A

11 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $8,536 · Current $8,536
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:  a) This violation occurred on or about May 9, 2018, and at times prior thereto; in the cable shop, where employee, who was working from the top of the Baler machine close to the edge, was not protected from falling to the ground below.
Recent events (2)
  • — C (S) $8536
  • — Z (S) $8536

1910.146 C04

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  a)  This violation occurred on or about May 9, 2018, and at times prior thereto; the employer did not implement their written permit required confined space entry program for employees who were working inside the confined space/Baler machine.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) This violation occurred on or about May 9, 2018, and at times prior thereto; the employer did not conduct a period inspection of the energy control procedure for Sweed machine at least annually.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $7,114 · Current $7,114
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolated:  a) On or about May 9, 2018, and at times prior thereto; the employer did not ensure that employees performing servicing, maintenance and/or clearing jam were trained. Employees were exposed to struck-by, crushed-by moving parts, while performing work on Baler machine.
Recent events (2)
  • — C (S) $7114
  • — Z (S) $7114

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) The employer did not ensure that lockout or tagout devices are affixed to each isolating device by authorized employees. This violation occurred on or about May 9, 2018, when lockout and/or tagout devices were not utilized by at least one (1) authorized employee clearing jam to the Baler machine.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.147 F03 II D

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment:  a) The employer did not ensure that each authorized employee affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment. This violation occurred on or about May 9, 2018, when lockout and/or tagout devices were not utilized by each authorized employee clearing jam to the Baler machine.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) The employer did not ensure that each powered industrial truck operator has successfully completed the training program consisting of a combination of formal instruction, practical training, and evaluation. This violation occurred on or about May 9, 2018 and at times prior thereto; when employees were operating the forklifts without having formal instruction, practical training and evaluation.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $7,114 · Current $7,114
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  The employer did not close unused openings on electrical equipment.  This violation occurred on or about May 9, 2018,  and at times prior thereto; in the cable shop, electrical box used to provide power to Harris Baler machine had unused openings at the side of the box.
Recent events (2)
  • — C (S) $7114
  • — Z (S) $7114

1910.305 B02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,959 · Current $9,959
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a) This violation was observed on or about May 9, 2018, in the compressor area/maintenance shop; where electrical panel box was not covered.
Recent events (2)
  • — C (S) $9959
  • — Z (S) $9959

1910.23 B10

Repeat Gravity 5 1 instance 2 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $17,071 · Current $17,071
29 CFR 1910.23(b)(10): Ladders having defects were not marked and taken out of service until repaired:  a) This violation occurred on or about May 9, 2018, and at times prior thereto; in the cable shop, Baler area, where employees used a metal stepladder that had damaged on the left foot, exposing employees to the hazards of falling.  The Venture Metals, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.26(c)(2)(vii), which was contained in OSHA inspection number 1077524, citation number 1, item number 2 and was affirmed as a final order on 01/25/2016, with respect to a workplace located at 1970 Crown Road, Farmers Branch, TX 75234.
Recent events (2)
  • — C (R) $17071
  • — Z (R) $17071

1910.178 P01

Repeat Gravity 10 1 instance 2 exposed
Issued
Oct 22, 2018
Abate by
Nov 1, 2018
Penalty
Initial $19,918 · Current $19,918
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  a) The employer did not ensure that power industrial trucks found to be in need of repair, defective, or anyway unsafe be taken out of service until restored to a safe operating condition. This violation occurred on or about May 9, 2018; when employees operated a Toyota forklift, model 7FDU70, SN 60239 that found to be in need of repair/defective had not been taken out of service.  The Venture Metals, LLC  was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.178(p)(1), which was contained in OSHA inspection number 1085029, citation number 1, item number 2 and was affirmed as a final order on 01/20/2016, with respect to a workplace located at 1970 Crown Road, Farmers Branch, TX 75234.