On , OSHA opened a referral health inspection of PCI PROCOATERS, INC. in 5259 MINOLA DRIVE, LITHONIA, GA 30038 (NAICS 332322). OSHA activity number 343131538.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCI PROCOATERS, INC.
- Site address
- 5259 MINOLA DRIVE
- City
- LITHONIA
- State
- GA
- ZIP
- 30038
- Mailing
- 5259 MINOLA DRIVE, LITHONIA, GA 30038
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 95
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.252 A02 IV
- Issued
- May 30, 2018
- Penalty
- Initial $4,205 · Current $2,523 Reduced
0430
General-duty citation text
29 CFR 1910.252(a)(2)(iv): The individual responsible for authorizing cutting or welding operations did not designate precautions to be followed in granting authorization to proceed preferably in the form of a written permit: PCI Procoaters, Inc., Lithonia, GA - Maintenance employees were cutting and assisting during the cutting of the top of 55 gal metal containers, such as but not limited to, drums that used to contained MEK. The precautions to be followed in granting authorization to perform the cutting was not provided, on or about 4/26/18.
Recent events (2)
- — I (S) $2523
- — Z (S) $4205
1910.252 A02 VI C
- Issued
- May 30, 2018
- Penalty
- Initial $4,205 · Current $2,523 Reduced
0430
General-duty citation text
29 CFR 1910.252(a)(2)(vi)(C): Cutting or welding was permitted in the presence of explosive atmospheres (mixture of flammable gases, vapors, liquids, or dusts with air), or explosive atmospheres that could develop inside uncleaned or improperly prepared tanks or equipment which had previously contained such materials: PCI Procoaters, Inc., Lithonia, GA - Maintenance employees were cutting and assisting during the cutting of the top of 55 gal metal containers, such as but not limited to, drums that used to contained MEK. The employer did not assure that the all the drums were properly cleaned and free of any flammable vapors and/or liquid, on or about 4/26/18.
Recent events (2)
- — I (S) $2523
- — Z (S) $4205
More inspections at PCI Procoaters, INC.
View PCI Procoaters, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343131538.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.