On , OSHA opened a referral safety inspection of INCA PRESSWOOD-PALLETS, LTD. in 3005 PROGRESS STREET, DOVER, OH 44622 (NAICS 321920). OSHA activity number 343137113.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inca Presswood-Pallets, LTD. — free Get an email when a new federal OSHA severe-injury report for Inca Presswood-Pallets, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
3005 PROGRESS STREET
City
DOVER
State
OH
ZIP
44622
Mailing
PO BOX 248, DOVER, OH 44622
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
34
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 17, 2018
Penalty
Initial $9,054 · Current $5,885 Reduced
29 CFR 1910.147(c)(4): Energy control procedure.  29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section:   On or about April 25, 2018, the employer's machine specific energy control procedure for the Deflasher did not include specific procedural steps for isolating and blocking stored mechanical energy and did not include the specific procedural steps for the placement of devices such as hardware for controlling stored mechanical energy. The Deflasher "table" when in the "up" position was subject to gravitational force that was released in an injury accident during machine servicing activities covered by this part.
Recent events (2)
  • — I (S) $5885.1
  • — Z (S) $9054

1910.147 C05 I

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c): General -  29 CFR 1910.147(c)(5): Protective materials and hardware.  29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.  On or about April 25, 2018, the employer's energy control program did not include and the employer failed to provide protective materials and hardware for use in isolating and blocking stored mechanical energy for covered activities involved with servicing and maintenance activities for the Deflasher. Employees performing covered activities, such as switch replacement, had potential exposure to stored mechanical energy when the Deflasher "table" was in the "up" position and not isolated or blocked with appropriate protective material or hardware.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 17, 2018
Abate by
Sep 13, 2018
Penalty
Initial $9,054 · Current $5,885 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about May 3, 2018, the employer failed to conduct a periodic inspection of the machine specific energy control procedure for the Deflasher, such as but not limited to including the control of mechanical energy related to the Deflasher component known as the "table." Employees have potential exposure to stored mechanical energy associated with the "table" being positioned in the "up" position during servicing and maintenance activities covered by this part.
Recent events (2)
  • — I (S) $5885.1
  • — Z (S) $9054

1910.147 C07 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 17, 2018
Abate by
Sep 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about April 25, 2018, the employer had not assured that authorized employees received training in the recognition of stored mechanical energy sources and the related means necessary for isolation and control of those sources, such as but not limited to, those related to the Deflasher. Employees performing covered activities, such as switch replacement, had potential exposure to stored mechanical energy when the Deflasher "table" was in the "up" position and not isolated or blocked with appropriate protective material or hardware.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 2 instances 1 exposed
Issued
Aug 17, 2018
Penalty
Initial $9,054 · Current $5,885 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.  a. On or about April 25, 2018, a maintenance employee performing activities covered by this part, failed to affix an energy isolating device as part of the employer's energy control procedure for the Deflasher machine. During the maintenance and servicing actiivities associated with diagnosis, switch removal and switch replacement, an energy isolating device, such as a lock, tag, or a locked or tagged hasp, was not affixed to the electrical disconnect for this equipment. Due to this condition, the maintenance employee had potential exposure to caught-in, struck-by and potential crushing hazards.   b. On or about April 25, 2018,  energy isolating devices or equipment were not utilized by a maintenance employee performing activities covered by this part to isolate and control stored mechanical energy associated with the "Table" component for the Deflasher machine during this covered activity. During the maintenance and servicing actiivities associated with diagnosis, switch removal and switch replacement, the employee was exposed to caught-in, struck-by and crushing hazards associated with the stored mechanical energy from the "Table" component.
Recent events (2)
  • — I (S) $5885.1
  • — Z (S) $9054

1910.147 F03 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 17, 2018
Abate by
Sep 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3): Group lockout or tagout.   29 CFR 1910.147(f)(3)(ii): Group lockout or tagout devices shall be used in accordance with the procedures required by paragraph (c)(4) of this section including, but not necessarily limited to, the following specific requirements:  29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.  On or about April 25, 2018, a maintenance employee and a shift supervisor failed to affix personal lockout (or tagout) devices to a group lockout device, group lockbox or other comparable device prior to performing covered activities  involved with servicing and maintenance activities for the Deflasher. These employees performed covered activities that involved potential exposure to caught-in hazards associated with an unexpected startup of the machine and stored mechanical energy when the Deflasher "table" was in the "up" position.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Inca Presswood-Pallets, LTD.'s full OSHA safety record →