On , OSHA opened a planned safety inspection of EASTON SAWYER CONSTRUCTION FIRM, LLC. in 117 SASSAFRASS WAY, BRIDGEPORT, WV 26330 (NAICS 238130). OSHA activity number 343139200.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Easton Sawyer Construction Firm, LLC. — free Get an email when a new federal OSHA severe-injury report for Easton Sawyer Construction Firm, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
117 SASSAFRASS WAY
City
BRIDGEPORT
State
WV
ZIP
26330
Mailing
PO BOX 1190, HEDGESVILLE, WV 25427
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.150 C01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1926.150(c)(1)(iv): One or more fire extinguishers, rated not less than 2A, were not provided on each floor:    a.) 117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, fire extinguishers were not provided during the construction of new four story wood frame apartment complex.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $3,696 · Current $2,218 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     a.)  117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, employees were exposed to falls of 44 feet to ground while installing sheeting on the roof of an apartment complex with no fall protection.
Recent events (2)
  • — I (S) $2217.6
  • — Z (S) $3696

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a.)  117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, employees installing sheeting on the roof of a new construction apartment building had not been trained in fall hazards or the procedures to be followed to minimize the hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $2,956 · Current $1,774 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a.) 117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, employees were exposed to falls of 9 feet to the floor below while stepping over / near 14 inch x 15 inch holes in the floor leading from the stairwell of the fourth floor to the housing area, to gain access to the roof.
Recent events (2)
  • — I (S) $1773.6
  • — Z (S) $2956

1926.1052 C01 I

Serious Gravity 5 2 instances 1 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $2,956 · Current $1,774 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:    a.) 117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, no handrail was provided on the 47 inch wide stairway with 19 risers, leading from ground to second floor.
Recent events (2)
  • — I (S) $1773.6
  • — Z (S) $2956

1926.1052 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 25, 2018
Abate by
Jul 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a.) 117 Sassafrass Way, Bridgeport WV:  On or about 05/02/18, no stairrail was provided on the 47 inch wide stairway with 19 risers, leading from ground to second floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Easton Sawyer Construction Firm, LLC.'s full OSHA safety record →