OSHA Inspection: HIGHER GROUND ROOFING INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HIGHER GROUND ROOFING INC. in 307 W MAIN ST, MERRILL, WI 54452 (NAICS 238160). OSHA activity number 343142337.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Higher Ground Roofing INC. — free Get an email when a new federal OSHA severe-injury report for Higher Ground Roofing INC. is published. One employer, no account, unsubscribe in one click.
Site address
307 W MAIN ST
City
MERRILL
State
WI
ZIP
54452
Mailing
9638 N. PARADISE RD., KEWASKUM, WI 53040
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Jun 8, 2018
Abate by
Jul 9, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    a.  On or about May 7, 2018, employees engaged in residential construction activities on a steep pitch roof, with unprotected sides and edges greater than fifteen feet above the ground at the jobsite located at 307 W Main St Merrill, WI were not protected from falling by an acceptable form of fall protection.  Two employees engaged in roofing activities were exposed to falls when a personal fall arrest system was not used.    b.  On or about May 7, 2018, employees engaged in roofing activities on a steep pitch roof, with unprotected sides and edges greater than fifteen feet above the ground at the jobsite located at 307 W Main St Merrill, WI were not protected from falling by an acceptable form of fall protection. The employer did not use a complete and properly installed fall protection during roofing work. Employees engaged in roofing activities were exposed to falls when the Guardian Temper Anchor Part #00455 used as part of the personal fall arrest system were not properly installed.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1926.502 D17

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 8, 2018
Abate by
Jul 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt shall be located in the center of the wearer's back. The attachment point of the body harness shall be located in the center of the wearer's back near shoulder level, or above the wearer's head.  a.  On or about May 7, 2018, employees engaged in residential construction activities on a steep pitch roof, with unprotected sides and edges greater than fifteen feet above ground at the jobsite located at 307 W Main St Merrill, WI were not protected from falling by an acceptable form of fall protection.  Four employees were wearing harnesses where the dee-ring was not located in the center of the wearer's back near shoulder level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D21

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 8, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems shall be inspected prior to each use for wear, damage and other deterioration, and defective components shall be removed from service.    a.  On or about May 7, 2018, an employee engaged in residential construction activities on a steep pitch roof with unprotected sides and edges greater than fifteen feet above the ground at the jobsite located at 307 W Main St Merrill, WI was wearing a harness that had a broken dee-ring pad.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1926.503 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 8, 2018
Abate by
Jul 9, 2018
Penalty
Initial $5,174 · Current $2,587 Reduced
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.    a.  On or about May 7, 2018, the employer did not verify that employees engaged in roofing activities had been trained in the hazards associated with falls from heights.
Recent events (2)
  • — I (S) $2587
  • — Z (S) $5174

1904.40 A

Deleted Other-than-serious 1 instance 15 exposed
Issued
Jun 8, 2018
Abate by
Jul 9, 2018
Penalty
Initial $739 · Current $0 Reduced
29 CFR 1904.40(a): Basic requirement. When an authorized government representative asks for the records you keep under Part 1904, you must provide copies of the records within four (4) business hours.  a.   On or about May 7, 2018,  the employer did not provide copies of annual OSHA injury and illness surveys when requested.
Recent events (2)
  • — I (O) $0
  • — Z (O) $739

View Higher Ground Roofing INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343142337.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.