Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUIKRETE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of QUIKRETE in 1008 US-67, ALVARADO, TX 76009 (NAICS 327320). OSHA activity number 343145116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quikrete — free Get an email when a new federal OSHA severe-injury report for Quikrete is published. One employer, no account, unsubscribe in one click.
Establishment
QUIKRETE
Site address
1008 US-67
City
ALVARADO
State
TX
ZIP
76009
Mailing
1008 US-67, ALVARADO, TX 76009
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
127
Ownership type
A

2 citations on file for this inspection.

1910.147 A02 II B

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2018
Abate by
Jun 8, 2018
Penalty
Initial $6,652 · Current $0 Reduced
29 CFR 1910.147(a)(2)(ii)(B): Lockout/tagout procedures were not implemented when servicing and/or maintenance was taking place during normal production operations when an employee was required to place any part of his/her body into an area on a machine or piece of equipment's point of operation or where an associated danger zone existed during a machine operating cycle.      At a facility located 1008 US-67, Alvarado, Texas:  at the E palletizer machine, the employer did not ensure the lock-out/tag-out procedures were followed during cleaning of the machine sensor exposing the employee to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6652

1910.147 C07 III B

Deleted Other-than-serious 1 instance 4 exposed
Issued
May 21, 2018
Penalty
Initial $793 · Current $0 Reduced
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures.       At a facility located 1008 US-67, Alvarado, Texas:  the employer did not ensure adequate or continued training for energy control purposes, function, recognition of energy sources, removal of energy and the use of the energy control program and procedures were utilized exposing employees to caught-in/amputation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $793

View Quikrete's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343145116.