LOVELAND, CO —
OSHA Inspection: GENESIS HOSPITALITY CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GENESIS HOSPITALITY CORPORATION in 4004 MEDFORD DRIVE, LOVELAND, CO 80538 (NAICS 337110). OSHA activity number 343152948.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENESIS HOSPITALITY CORPORATION
- Site address
- 4004 MEDFORD DRIVE
- City
- LOVELAND
- State
- CO
- ZIP
- 80538
- Mailing
- 4004 MEDFORD DRIVE, LOVELAND, CO 80538
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 80
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.106 D04 I
- Issued
- Oct 9, 2018
- Abate by
- Oct 30, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings were not provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which drains to a safe location. Where other portions of the building or other properties are exposed, windows shall be protected as set forth in the Standard for Fire Doors and Windows, NFPA No. 80-1968, which is incorporated by reference as specified in Sec. 1910.6, for Class E or F openings. Wood at least 1 inch nominal thickness was not used for shelving, racks, dunnage, scuffboards, floor overlay, and similar installations. (a) Genesis Hospitality Corporation., at 4004 Medford Drive, Loveland, CO 80538: On and before April 10, 2018, the employer did not ensure that the approved fire door on the west wall inside the flammables storage room (Kitchen) was self-closing and that the wood shelving was a minimum of 1 inch nominal thickness in that employees outside the flammables storage room were not adequately protected from fire hazards because the west door lacked a door closer and the shelves used to store flammable liquids was only 5/8 inch thick.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.212 A01
- Issued
- Oct 9, 2018
- Abate by
- Oct 30, 2018
- Penalty
- Initial $6,467 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operators and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Genesis Hospitality Corporation., at 4004 Medford Drive, Loveland, CO 80538: On and before April 10, 2018, the employer did not ensure that machine guarding was provided to protect operators and other employees from hazards created by point of operation, in that the guillotine cutter on the Edge Bander machine exposed employees to shearing action hazards from a pneumatic operated knife blade. This condition exposed the employees to laceration and amputation hazards.
Recent events (2)
- — I (S) $3500
- — Z (S) $6467
More inspections at Genesis Hospitality Corporation
View Genesis Hospitality Corporation's full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343152948.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.