Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROOF-OVER AMERICA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROOF-OVER AMERICA, LLC in 350 ANCHOR RD, CASSELBERRY, FL 32707 (NAICS 238160). OSHA activity number 343155768.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roof-Over America, LLC — free Get an email when a new federal OSHA severe-injury report for Roof-Over America, LLC is published. One employer, no account, unsubscribe in one click.
Site address
350 ANCHOR RD
City
CASSELBERRY
State
FL
ZIP
32707
Mailing
1001 WEST NEW HAMPSHIRE, ORLANDO, FL 32804
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

8 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 7 exposed
Issued
Jul 24, 2018
Penalty
Initial $5,691 · Current $2,846 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:   a. At the site located at 350 Anchor Rd, Casselberry, Florida, employees were exposed to a 16  foot fall hazard, in that, while working on a roof 300 feet wide by 300 feet long employees were handling roofing material and doing repair work right at the edge of the roof without fall protection, on or about 05/08/2018.
Recent events (2)
  • — I (S) $2845.5
  • — Z (S) $5691

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:   a. At the site located at 350 Anchor Rd, Casselberry, Florida, an employee was exposed to a fall hazard, in that, employees were allowed to work near the edge of the roof while using a personal fall arrest system with an allowed fall arrest distance of over 7 feet, on or about 05/08/2018.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 10 1 instance 7 exposed
Issued
Jul 24, 2018
Penalty
Initial $5,691 · Current $2,846 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    a. At the site located at 350 Anchor Rd, Casselberry, Florida, employees exposed to fall hazards, were not provided training and education relating to fall protection, hazard recognition, procedures to be followed to minimize these hazards and the proper use and limitations of fall protection equipment and fall protection systems:  1. During roofing work employees were exposed to fall hazards while on the roof outside the control access area; 2. A monitor system was used on a roof over 50 feet in width; 3. While using a fall arrest system a fall arrest distance greater than 6 feet was allowed; 4. The monitor did not stay close to where the work was done and at times he was about 100 feet away from the workers; 5. While handling, removing old panels and setting up a safe walkway on the roof, employees were exposed to a fall hazard.  On or about 05/08/2018.
Recent events (2)
  • — I (S) $2845.5
  • — Z (S) $5691

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Jul 24, 2018
Penalty
Initial $4,065 · Current $2,036 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:   a. On or about 10:45 a.m. on 04/24/2018, at 350 Anchor Rd, Casselberry, Florida, an employee suffered a work related injury and was hospitalized. The employer was aware of the injury and hospitalization on the same day of the incident. The employer notified OSHA on 05/04/2018 of the in-patient hospitalization.
Recent events (2)
  • — I (O) $2035.5
  • — Z (O) $4065

1910.1200 E01

Other-than-serious 1 instance 11 exposed
Issued
Jul 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59)     a. At the site, employees were exposed to chemical products such as, but not limited to, oxygen, acetylene, diesel fuel, gasoline and butyl rubber. A written hazard communication program was not developed, implemented and maintained at the workplace, on or about 05/08/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 11 exposed
Issued
Jul 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:   a. At the site, employees were exposed to chemical products such as, but not limited to, oxygen, acetylene, diesel fuel, gasoline and butyl rubber. An inventory list of the chemical products used by employees was not developed and maintained on or about 05/08/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 11 exposed
Issued
Jul 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)    a. At the site, employees were exposed to chemical products such as, but not limited to, oxygen, acetylene, diesel fuel, gasoline and butyl rubber. Employees were not provided training and education on the hazardous chemicals at the workplace, on or about 05/08/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.51 A04

Other-than-serious 1 instance 7 exposed
Issued
Jul 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.51(a)(4): The common drinking cup was not prohibited:  a. At the site located at 350 Anchor Rd, Casselberry, Florida, employees were exposed to communicable diseases, in that, the employees were not provided with drinking cups and were drinking water from the cooler, on or about 05/08/2018.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Roof-Over America, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343155768.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.