MIAMI, FL —
OSHA Inspection: REMINGTON STEEL AND SIGNS LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of REMINGTON STEEL AND SIGNS LLC. in 2250 NW 77TH TERRACE, MIAMI, FL 33147 (NAICS 332312). OSHA activity number 343159067.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REMINGTON STEEL AND SIGNS LLC.
- Site address
- 2250 NW 77TH TERRACE
- City
- MIAMI
- State
- FL
- ZIP
- 33147
- Mailing
- 2250 NW 77TH TERRACE, MIAMI, FL 33147
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 14
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 A04
- Issued
- Aug 30, 2018
- Abate by
- Sep 19, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, a forklift with an attachment was not approved by the manufacturer and being used to move material at the yard.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.253 B04 III
- Issued
- Aug 30, 2018
- Abate by
- Sep 19, 2018
- Penalty
- Initial $4,434 · Current $2,660 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop oxygen cylinders are being stored together with acetylene, and compress gas cylinders thereby exposing employees to a fire hazard.
Recent events (2)
- — I (S) $2660.4
- — Z (S) $4434
1910.305 B01 II
- Issued
- Aug 30, 2018
- Abate by
- Sep 19, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop an electrical outlet box with open knockout rings, and exposed electrical cables was being used to connect hand tools, exposing the employee to an electrical shock hazard.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.37 A03
- Issued
- Aug 30, 2018
- Abate by
- Sep 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the welding department employees were exposed to the obstructed hazard of being trapped in the event of a fire by steel trusses where the exit doors are located impeding egress in case of emergency.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Aug 30, 2018
- Abate by
- Sep 19, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: On or about 5/10/2018, at jobsite location 2250 NW 77th Terrace, Miami, FL 33147, in the machine shop flexible cord were run throughout a wall hole to energize hand tools.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Remington Steel and Signs LLC.
View Remington Steel and Signs LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343159067.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.