PREBLE, NY —
OSHA Inspection: PAUL BUNYAN PRODUCTS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAUL BUNYAN PRODUCTS INC. in 7101 NYS ROUTE 281, PREBLE, NY 13141 (NAICS 321920). OSHA activity number 343165460.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAUL BUNYAN PRODUCTS INC.
- Site address
- 7101 NYS ROUTE 281
- City
- PREBLE
- State
- NY
- ZIP
- 13141
- Mailing
- 890 MCLEAN ROAD, CORTLAND, NY 13045
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 29
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.25 C04
- Issued
- Jun 19, 2018
- Abate by
- Jul 9, 2018
- Penalty
- Initial $5,544 · Current $3,326 Reduced
General-duty citation text
29 CFR 1910.25(c)(4): Standard stairs did not have a minimum width of 22 inches (56 cm) between vertical barriers: a) Pallet Line #2, on or about 5/16/18: Two fixed stairways to the nail bowls along pallet line #2 did not have a minimum width of 22 inches between the vertical barriers in that they measured 17 inches and 20 inches wide on each of the stairways. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $3326.4
- — Z (S) $5544
1910.28 B11 II
- Issued
- Jun 19, 2018
- Abate by
- Jul 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required in Table D-2 of this standard: a) Pallet Line #1, on or about 5/16/18: Two fixed stairways with four risers to the work platform were not provided with stair rail systems. b) Pallet Line #2, on or about 5/16/18: Two fixed stairways with five risers to the work platforms for the nail bowls along pallet line #2 were not provided with a stair railing on the right side descending. c) Pallet Line #2, on or about 5/16/18: A fixed stairway with four risers to the work platform was not provided with a stair rail system. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 19, 2018
- Abate by
- Jul 9, 2018
- Penalty
- Initial $9,239 · Current $5,543 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Main Saw Area, on or about 5/16/18: Conveyor belt with metal lacings and pulley parts were not fully guarded on the Brewer gang saw waste belt in that there were openings on the sides of the belt at the tail pulley. b) Main Saw Area, on or about 5/16/18: Ingoing nip points at the infeed chain on the Brewer multi trim saw were not adequately guarded in that the existing guard did not enclose the nip points between the chain and sprocket. c) Main Saw Area, on or about 5/16/18: Conveyor belt with metal lacings and pulley parts were not guarded at the notcher feed conveyor coming off from the gang saw conveyor. d) Pallet Line #1, on or about 5/16/18: Ingoing nip points at the infeed chain to stacker were not guarded. e) Pallet Line #2, on or about 5/16/18: Ingoing nip points at the infeed chain to stacker were not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $5543.4
- — Z (S) $9239
1910.303 B07 IV
- Issued
- Jun 19, 2018
- Abate by
- Jul 9, 2018
- Penalty
- Initial $5,544 · Current $3,326 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: a) Pallet Line #2, on or about 5/16/18: Flexible conduit at the stringer loader along pallet line #2 was broken at the fitting and unraveling, exposing conductors to damage. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $3326.4
- — Z (S) $5544
1910.305 B02 I
- Issued
- Jun 19, 2018
- Abate by
- Jun 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Pallet Line 2, on or about 5/16/18: Condulet cover was up out of position, at the lead board and positioner area, exposing conductors to damage. b) Pallet Line 1, on or about 5/16/18: Condulet cover was missing at the boar feed sensor area, exposing conductors to damage. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Paul Bunyan Products INC.
View Paul Bunyan Products INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343165460.