Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROWN ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CROWN ROOFING LLC in 4921-4935 WINDERMERE AVE., KISSIMMEE, FL 34746 (NAICS 238160). OSHA activity number 343167276.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crown Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Crown Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CROWN ROOFING LLC
Site address
4921-4935 WINDERMERE AVE.
City
KISSIMMEE
State
FL
ZIP
34746
Mailing
8621 E. DR. MARTIN LUTHER KING BOULEVARD, TAMPA, FL 33610
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.405 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $6,098 · Current $4,269 Reduced
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used:    a. On or about 05/17/2018, at 4921-4935 Windermere Ave. - an employee was exposed to an electric contact hazard while using a flexible cord that was spliced together. The two flexible cords were connected using electric black tape due to a damaged cord plug.
Recent events (2)
  • — I (S) $4268.6
  • — Z (S) $6098

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $129,336 · Current $90,535 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a. Employees installing roofing tiles at elevations of six feet or more above the ground are not being protected from fall hazards by a fall protection system: The employer fails to assure effective protection against falls as required by the standard, as demonstrated on May 17, 2018, when employees installing roofing tiles on the 6:12 pitch roof of a house at 4921-4935 Windermere Ave. in Kissimmee, Florida, were exposed to the hazard of a 19 foot 2 inch fall to the ground in that they did not have roof anchor points to attach personal fall arrest gear.      Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(11), which was contained in OSHA Inspection number 1136266, Citation Number 01, Item Number 001 and was affirmed as a final order on 09/12/2016, with respect to a workplace located at Courtyard Esterro Apartments Building 17, Corkscrew Commons Drive, Estero, FL 33928.      Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA Inspection number 1115276, Citation Number 01, Item Number 001 and was affirmed as a final order on 04/01/2016, with respect to a workplace located at 6622 Everton Court, Fort Myers, FL 33966.    Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA Inspection number 1028907, Citation Number 02, Item Number 001 and was affirmed as a final order on 01/19/2016, with respect to a workplace located at 10525 NW 66th St., Doral, FL 33172.     Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(B)(01), which was contained in OSHA Inspection number 1062819, Citation Number 01, Item Number 001 and was affirmed as a final order on 11/17/2015, with respect to a workplace located at 6650 N.W. 106 Ave., Miami, FL 33178.    Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(B)(13), which was contained in OSHA Inspection number 970750, Citation Number 01, Item Number 001 and was affirmed as a final order on 05/22/2015 with respect to a workplace located at 13127 Bridgeport Crossing, Lakewood Ranch, FL 34202.    Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(B)(13), which was contained in OSHA Inspection number 1044419, Citation Number 01, Item Number 01, Item Number 001 and was affirmed as a final order on 04/03/2015, with respect to a workplace located at 1345 Shinnecock Hills Dr., Davenport, FL 33896.      Crown Roofing LLC was cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(B)(11), which was contained in OSHA Inspection number 968871, Citation Number 01, Item Number 001 and was affirmed as a final order on 06/10/2014, with respect to a workplace located at 1317 Moss Creek Lane, Lot-C115 & Lot-C165, Champions Gate, FL 33896.
Recent events (2)
  • — I (R) $90535.2
  • — Z (R) $129336

1910.134 E01

Other-than-serious 1 instance 4 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103):  a. On or about 05/17/2018, at 4921-4935 Windermere Ave. - the employer did not conduct medical evaluations for employees required to use respirators while cutting roofing tiles.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 4 exposed
Issued
Sep 19, 2018
Abate by
Oct 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103):  a. On or about 05/17/2018, at 4921-4935 Windermere Ave. - the employer did not fit test employees to use respirators while cutting roofing tiles.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Crown Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343167276.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.