MANSFIELD, PA —
OSHA Inspection: SWAMINARAYAN BAPA CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SWAMINARAYAN BAPA CORP. in 1424 SOUTH MAIN STREET, MANSFIELD, PA 16933 (NAICS 722513). OSHA activity number 343176277.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SWAMINARAYAN BAPA CORP.
- Site address
- 1424 SOUTH MAIN STREET
- City
- MANSFIELD
- State
- PA
- ZIP
- 16933
- Mailing
- 2750 WESTINGHOUSE ROAD SUITE B, HORSEHEADS, NY 14845
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722513
- Employees
- 16
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 4, 2018
- Abate by
- Jun 22, 2018
- Penalty
- Initial $9,239 · Current $6,467 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees operated a natural gas fired oven while exposed to slip, trip, fall, burn and explosion hazards: a) Kitchen, 1424 South Main Street, Mansfield, PA - Employees operated a castered Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) without a restraint (safety device) to prevent strain from being imparted onto the natural gas supply line and connections to the appliance exposing the employees to burn and explosion hazards, on or about May 22, 2018. b) Kitchen, 1424 South Main Street, Mansfield, PA - Employees operated a castered Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) with a water drain directly beneath the oven exposing the employees to slip, trip, and fall hazards, on or about May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (S) $6467.3
- — Z (S) $9239
1910.303 B02
- Issued
- Jun 4, 2018
- Abate by
- Jun 28, 2018
- Penalty
- Initial $5,543 · Current $3,880 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Kitchen, 1424 South Main Street, Mansfield, PA - The energized power cord of the Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) lacked strain relief and had been abraided by the non-metallic cable clamp type connector that was not being used in accordance with its listing or labeling exposing employees to a contact with electrical current hazard, on or about May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (S) $3880.1
- — Z (S) $5543
1910.305 G01 IV A
- Issued
- Jun 4, 2018
- Abate by
- Jun 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Kitchen, 1424 South Main Street, Mansfield, PA - Employees used the Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) that was energized by an extension cord used in lieu of fixed wiring exposing employees to a contact with electrical current hazard, on or about May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.40 A
- Issued
- Jun 4, 2018
- Abate by
- Jun 8, 2018
- Penalty
- Initial $1,848 · Current $1,294 Reduced
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours: a) Facility, 1424 South Main Street, Mansfield, PA - On or about May 22, 2018, the employer failed to provide copies of the injury and illness records to an authorized representative within four (4) hours after the initial request on May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (O) $1293.6
- — Z (O) $1848
1910.263 L09 II
- Issued
- Jun 4, 2018
- Abate by
- Jun 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.263(l)(9)(ii): All safety devices on the oven were not inspected at intervals of not less than twice a month by a properly instructed bakery employee or at intervals of not less than once a year by a representative of the oven manufacturer: a) Kitchen, 1424 South Main Street, Mansfield, PA - Employees operated a Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) with safety devices (restraint, gas inlet pressure valve, manifold pressure valve, water pressure valve, etc.) that had never been inspected since the oven had been installed in February, 2013 exposing the employees to natural gas, on or about May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.263 L09 V B
- Issued
- Jun 4, 2018
- Abate by
- Jun 22, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.263(l)(9)(v)(b): The safety shutoff valve in the fuel line was not tested at least twice monthly: a) Kitchen, 1424 South Main Street, Mansfield, PA - Employees operated a Blodgett Oven Company Model XR8G/AB Mini Rack Oven (Serial No. 092412DJ0927) with a natural gas safety shutoff valve that had never been tested since the oven had been installed in February, 2013 exposing the employees to natural gas, on or about May 22, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Swaminarayan Bapa Corp.
View Swaminarayan Bapa Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 722513)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343176277.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.