OSHA Inspection: RCI READY CABLE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RCI READY CABLE INC. in 4337 DIRECTOR, SAN ANTONIO, TX 78219 (NAICS 238190). OSHA activity number 343183901.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RCI Ready Cable INC. — free Get an email when a new federal OSHA severe-injury report for RCI Ready Cable INC. is published. One employer, no account, unsubscribe in one click.
Site address
4337 DIRECTOR
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
4337 DIRECTOR, SAN ANTONIO, TX 78219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
10
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 1 instance 8 exposed
Issued
Aug 17, 2018
Abate by
Aug 27, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by flying projectiles:      Maintenance area:  On or about May 23, 2018, employees were exposed to the hazard of being struck by flying projectiles, while operating compressed air tools such as blow-off guns and tire inflators.  The compressed air used by the tools was transported above grade via 3/4" SCH 40 PVC JM Eagle Pipe.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1910.178 P01

Serious Gravity 5 5 instances 3 exposed
Issued
Aug 17, 2018
Abate by
Aug 27, 2018
Penalty
Initial $2,956 · Current $1,774 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):  a)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a JLG, Model, ST9 forklift, S/N:  679451HRA, which had defective rear tires and a defective horn.  b)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a Pro 5 forklift, S/N: 91, which had defective rear tires.  c)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a Komatsu forklift, Model PG1851-16, S/N: 73, which had a missing seatbelt.  d)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a JLG 6042 forklift, S/N: SA674157, which had a defective seatbelt and no back-up alarm.  e)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a forklift, S/N: 72 which had a defective seat slide.
Recent events (2)
  • — I (S) $1773.6
  • — Z (S) $2956

1910.178 Q07

Serious Gravity 5 5 instances 3 exposed
Issued
Aug 17, 2018
Abate by
Aug 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  a)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a JLG, Model, ST9 forklift, S/N:  679451HRA, which had defective rear tires and a defective horn.  b)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a Pro 5 forklift, S/N: 91, which had defective rear tires.  c)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a Komatsu forklift, Model PG1851-16, S/N: 73, which had a missing seatbelt.  d)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a JLG 6042 forklift, S/N: SA674157, which had a defective seatbelt and no back-up alarm.  e)  Throughout the work location:  On or about May 23, 2018, and at time prior thereto, employees were exposed to struck-by hazards while operating a forklift, S/N: 72 which had a defective seat slide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 17, 2018
Abate by
Aug 27, 2018
Penalty
Initial $2,956 · Current $1,774 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Circuit panel next to air compressor:  On or about May 23, 2018, and at times prior thereto, an employee was exposed to an electrical hazards while accessing a circuit breaker panel to switch on and off the air compressor.  The circuit breaker panel was missing circuit breaker blanks, exposing 240 Vac energized bus bar.
Recent events (2)
  • — I (S) $1773.6
  • — Z (S) $2956

View RCI Ready Cable INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343183901.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.