SAN ANTONIO, TX —
OSHA Inspection: RCI READY CABLE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RCI READY CABLE INC. in 4337 DIRECTOR DR., SAN ANTONIO, TX 78219 (NAICS 238190). OSHA activity number 346108699.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RCI READY CABLE INC.
- Site address
- 4337 DIRECTOR DR.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78219
- Mailing
- 4416 KELLER HICKS RD., FORT WORTH, TX 76244
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 260
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 E03
- Issued
- Sep 12, 2022
- Abate by
- Sep 30, 2022
- Penalty
- Initial $6,215 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.157(e)(3):The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request: On or about July 28, 2022, and at times prior thereto, employees were exposed to a fire hazard, while working in the shop, without the fire extinguishers subjected to an annual maintenance check.
Recent events (2)
- — I (S) $4000
- — Z (S) $6215
1910.219 E01 I
- Issued
- Sep 12, 2022
- Abate by
- Sep 30, 2022
- Penalty
- Initial $8,287 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard did not extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this section: On or about July 28, 2022, and at times prior thereto, employees were exposed to amputation hazards while operating the post-tensioning machine (brand unknown) without the horizontal power transmission pulleys not being guarded.
Recent events (2)
- — I (S) $7000
- — Z (S) $8287
1910.219 C04 I
- Issued
- Sep 12, 2022
- Abate by
- Sep 30, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends projected more than one-half the diameter of the shaft and were not guarded by nonrotating caps or safety sleeves: On or about July 28, 2022, and at times prior thereto, employees were exposed to caught in-between hazards while operating the post-tensioning machine without the projecting shafts ends on the power transmission pulleys being guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B02 II
- Issued
- Sep 12, 2022
- Penalty
- Initial $8,287 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders were not stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces were not located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about July 28, 2022, and at times prior thereto, employees were exposed to a fire hazard, while working in the shop, with oxygen and acetylene cylinders stored adjacent to each other.
Recent events (2)
- — I (O) $2000
- — Z (S) $8287
1910.303 F02
- Issued
- Sep 12, 2022
- Abate by
- Sep 30, 2022
- Penalty
- Initial $8,287 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: On or about July 28, 2022, and at times prior thereto, employees were exposed to the hazards of electric shock, or amputation, while working on machines in the shop, where the circuit breakers were not labeled.
Recent events (2)
- — I (O) $2000
- — Z (S) $8287
More inspections at RCI Ready Cable INC.
View RCI Ready Cable INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346108699.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.