OSHA Inspection: RCI READY CABLE INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RCI READY CABLE INC. in 4337 DIRECTOR DR., SAN ANTONIO, TX 78219 (NAICS 238190). OSHA activity number 346108699.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RCI Ready Cable INC. — free Get an email when a new federal OSHA severe-injury report for RCI Ready Cable INC. is published. One employer, no account, unsubscribe in one click.
Site address
4337 DIRECTOR DR.
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
4416 KELLER HICKS RD., FORT WORTH, TX 76244
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
260
Ownership type
A

5 citations on file for this inspection.

1910.157 E03

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2022
Abate by
Sep 30, 2022
Penalty
Initial $6,215 · Current $4,000 Reduced
29 CFR  1910.157(e)(3):The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request:  On or about July 28, 2022, and at times prior thereto, employees were exposed to a fire hazard, while working in the shop, without the fire extinguishers subjected to an annual maintenance check.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6215

1910.219 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 12, 2022
Abate by
Sep 30, 2022
Penalty
Initial $8,287 · Current $7,000 Reduced
29 CFR  1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard did not extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt was not fully enclosed in accordance with paragraphs (m) and (o) of this section:   On or about July 28, 2022, and at times prior thereto, employees were exposed to amputation hazards while operating the post-tensioning machine (brand unknown) without the horizontal power transmission pulleys not being guarded.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $8287

1910.219 C04 I

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 12, 2022
Abate by
Sep 30, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.219(c)(4)(i): Projecting shaft ends projected more than one-half the diameter of the shaft and were not guarded by nonrotating caps or safety sleeves:    On or about July 28, 2022, and at times prior thereto, employees were exposed to caught in-between hazards while operating the post-tensioning machine without the projecting shafts ends on the power transmission pulleys being guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Sep 12, 2022
Penalty
Initial $8,287 · Current $2,000 Reduced
29 CFR  1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders were not stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces were not located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  On or about July 28, 2022, and at times prior thereto, employees were exposed to a fire hazard, while working in the shop, with oxygen and acetylene cylinders stored adjacent to each other.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $8287

1910.303 F02

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Sep 12, 2022
Abate by
Sep 30, 2022
Penalty
Initial $8,287 · Current $2,000 Reduced
29 CFR  1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident:  On or about July 28, 2022, and at times prior thereto, employees were exposed to the hazards of electric shock, or amputation, while working on machines in the shop, where the circuit breakers were not labeled.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $8287

View RCI Ready Cable INC.'s full OSHA safety record →