Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EDGE LINEN SERVICES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EDGE LINEN SERVICES INC. in 2040 EDWIN AVENUE, FORT LEE, NJ 07024 (NAICS 812332). OSHA activity number 343192027.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Edge Linen Services INC. — free Get an email when a new federal OSHA severe-injury report for Edge Linen Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
2040 EDWIN AVENUE
City
FORT LEE
State
NJ
ZIP
07024
Mailing
2040 EDWIN AVENUE, FORT LEE, NJ 07024
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812332
Employees
35
Ownership type
A

12 citations on file for this inspection.

1910.25 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 14, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.25(b)(1): The employer did not ensure handrails, stair rail systems, and guardrail systems were provided in accordance with 1910.28:  a) 2nd Floor: Employees were exposed to fall hazards from a wooden stair case that was not secure to the landing, on or about 8/29/18.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.28 B01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 14, 2018
Penalty
Initial $7,760 · Current $4,656 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a) 2nd Floor: Employees were exposed to fall hazards in excess of 6 feet where employees were working near a loading dock door that was not protected by guard rails, gate, or other feasible means of fall protection, on or about 8/29/18.
Recent events (2)
  • — I (S) $4656
  • — Z (S) $7760

1910.28 B11 I

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.28(b)(11)(i): Each employee exposed to an unprotected side or edge of a stairway landing that was 4 feet (1.2 m) or more above a lower level was not protected by a guardrail or stair rail system:  a) 2nd Floor Exterior Stairs: Employees were exposed to fall hazards from a stair case where the hand rail was damaged on or about 8/29/18.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.37 A03

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 14, 2018
Penalty
Initial $7,760 · Current $4,656 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  a) 2nd Floor: Employees were exposed to fire hazards from exit routes and doors were not kept free and unobstructed. Routes and doors were blocked by large bins, on or about 8/29/18.
Recent events (2)
  • — I (S) $4656
  • — Z (S) $7760

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) 2nd Floor Ironing Machine: Employees were exposed to electrical hazards from a Jenson Corp. Ironing Machine that did not have procedures developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in servicing the machine , on or about 5/30/18.
Recent events (2)
  • — I (S) $5432.4
  • — Z (S) $9054

1910.179 J03

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $7,760 · Current $4,656 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  a) 2nd Floor Hoist: Employees were exposed to struck by hazards from a Pittsburg hoist that did not have a complete periodic inspection conducted in the past 12 months and showed signs of damage, on or about 5/30/18.
Recent events (2)
  • — I (S) $4656
  • — Z (S) $7760

1910.179 M01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.179(m)(1)(iv): Corroded or broken wires at end connections.  a) 2nd Floor Hoist: Employees were exposed to struck by hazards from a Pittsburg hoist with a damaged hoist cable, on or about 5/30/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $0 · Current $0
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees where employees were using a hoist with a hook that was missing a safety latch.  a) 2nd Floor Hoist: Employees were exposed to struck by hazards from a Pittsburg hoist with a cable hook was missing a safety latch, on or about 5/30/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 4 instances 6 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $9,054 · Current $5,432 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) 2nd Floor: Employees were exposed to amputation hazards from a TOM linen tying machine that was missing guards around the pulleys, on or about 5/30/18.  b) 2nd Floor: Employees were exposed to amputation hazards from a PAC washing machine that was missing guards around moving parts, on or about 5/30/18.  c) 2nd Floor: Employees were exposed to amputation hazards from a IPSO drying machine that was missing guards around moving parts, on or about 5/30/18.  d) 2nd Floor: Employees were exposed to amputation hazards from an Jenson Corp Model 382 ironing machine that was missing guards around moving parts, on or about 5/30/18.
Recent events (2)
  • — I (S) $5432.4
  • — Z (S) $9054

1910.303 G01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $5,174 · Current $0 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) 2nd Floor: Employees were exposed to electric shock hazards from electrical panels that did not have adequate access and working space, on or about 5/30/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5174

1910.303 G02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) 2nd Floor Hoist: Employees were exposed to electric shock hazards from electrical outlet and boxes that were not properly guarded by covers, on or about 5/30/18.  b) 2nd Floor Washer: Employees were exposed to electric shock hazards from electrical outlet that was not mounted in a box and protected by a cover, on or about 8/29/18.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Sep 14, 2018
Abate by
Nov 1, 2018
Penalty
Initial $5,174 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring :   a) 2nd Floor Hoist: Employees were exposed to electric shock hazards from a Pittsburgh electric hoist that was wired with an extension cord, on or about 5/30/18.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5174

View Edge Linen Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343192027.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.