MOSCOW MILLS, MO ·
OSHA Inspection: BCI PACKAGING
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BCI PACKAGING in 245 COLLEGE CAMPUS DRIVE, MOSCOW MILLS, MO 63362 (NAICS 561910). OSHA activity number 343194908.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BCI PACKAGING
- Site address
- 245 COLLEGE CAMPUS DRIVE
- City
- MOSCOW MILLS
- State
- MO
- ZIP
- 63362
- Mailing
- 245 COLLEGE CAMPUS DRIVE, MOSCOW MILLS, MO 63362
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561910
- Employees
- 55
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jul 12, 2018
- Abate by
- Aug 28, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: Lockout/tagout specific procedures were not developed and written for each specific machine, according to the requirements of 1910.147(c)(4)(ii)(A) through (D). (Also see Appendix A guidelines.) Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $0
- · Z (S) $12934
1910.147 C05 I
- Issued
- Jul 12, 2018
- Abate by
- Aug 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Pneumatic energy lockout devices, such as covers for air valves or end of lines, were not provided or available for energy isolation. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C06 I A
- Issued
- Jul 12, 2018
- Abate by
- Aug 28, 2018
- Penalty
- Initial $4,712 · Current $3,298 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: There was no periodic inspection specific to machines to be locked out and according to the specific requirements of the standard (1910.147(c)(6)(i)(A) through (C)); an annual review was not referred to or addressed in the company general lockout program. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $3298.4
- · Z (S) $4712
1910.147 C06 II
- Issued
- Jul 12, 2018
- Abate by
- Aug 28, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: There was no periodic inspection certification. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A03 I
- Issued
- Jul 12, 2018
- Abate by
- Aug 28, 2018
- Penalty
- Initial $12,934 · Current $9,054 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(i): The point of operation of machines whose operation exposes an employee to injury, was not guarded: The guard door safety switch to the Aesus machine was not functioning. An amputation occurred on this machine while the switch was not functioning, as an employee was exposed to the knife that cut plastic strips. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $9053.8
- · Z (S) $12934
More inspections at BCI Packaging
View BCI Packaging's full OSHA safety record →
More inspections in this industry (NAICS 561910)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343194908.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.