RUTHERFORD, NJ —
OSHA Inspection: ANGEL CEDILLO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANGEL CEDILLO in 30 WILLOW ST., RUTHERFORD, NJ 07070 (NAICS 238170). OSHA activity number 343196242.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANGEL CEDILLO
- Site address
- 30 WILLOW ST.
- City
- RUTHERFORD
- State
- NJ
- ZIP
- 07070
- Mailing
- 96 98 HILLSIDE TERRACE, IRVINGTON, NJ 07111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jul 9, 2018
- Penalty
- Initial $2,772 · Current $1,663 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Exterior of Building/Building Side: Employee was exposed to electrical shock and burns to the head while working from a pump jack scaffold approximately 2 feet from an energized electrical line, on or about 5/23/2018.
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
1926.451 F06
- Issued
- Jul 9, 2018
- Penalty
- Initial $3,881 · Current $2,329 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) Building Exterior/Side: Employees were using a Alum-A-Pole pump jack scaffold approximately 2 feet from an energized electrical line, on or about 5/23/2018.
Recent events (2)
- — I (S) $2328.6
- — Z (S) $3881
1926.451 G01
- Issued
- Jul 9, 2018
- Penalty
- Initial $2,772 · Current $1,663 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Building Exterior/Side: Employees exposed to a 16 foot fall hazard while working from an alum-a-pole pump jack scaffold that was not equipped with a guardrail system in place, on or about 5/23/2018.
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
1926.501 B13
- Issued
- Jul 9, 2018
- Penalty
- Initial $3,881 · Current $2,329 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Exterior of Building/Roof Front: An employee engaged with siding removal was exposed to a fall hazard of approximately 12 foot fall hazard while working on a setback roof without fall protection, on or about 5/23/2018.
Recent events (2)
- — I (S) $2328.6
- — Z (S) $3881
1926.1053 B01
- Issued
- Jul 9, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Exterior of Building/Building Side: An employee was using a ladder that did not extend 3 feet above the roof landing, on or about 5/23/2018.
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
More inspections at Angel Cedillo
View Angel Cedillo's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343196242.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.