Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAMMOND & IRVING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAMMOND & IRVING INC. in 254 NORTH STREET, AUBURN, NY 13021 (NAICS 332112). OSHA activity number 343197729.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hammond & Irving INC. — free Get an email when a new federal OSHA severe-injury report for Hammond & Irving INC. is published. One employer, no account, unsubscribe in one click.
Site address
254 NORTH STREET
City
AUBURN
State
NY
ZIP
13021
Mailing
254 NORTH STREET, AUBURN, NY 13021
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332112
Employees
70
Ownership type
A

4 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 5 2 instances 6 exposed
Issued
Jun 20, 2018
Abate by
Jul 10, 2018
Penalty
Initial $6,467 · Current $3,880 Reduced
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard of thermal burns:    a)  Press Department, on or about 6/1/18:   Employees are exposed to contact with flying scale and hot surfaces during forging operations in that they do not wear arm protection.     b)  Hammer Department, on or about 6/1/18:  Employees are exposed to contact with flying scale and hot surfaces during forging operations in that they do not wear arm protection.
Recent events (2)
  • — I (S) $3880.2
  • — Z (S) $6467

1910.133 A01

Serious Gravity 5 3 instances 14 exposed
Issued
Jun 20, 2018
Abate by
Oct 1, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a)  Press Department, on or about 6/1/18:   Employees are exposed to potentially injurious infrared light in that they were not wearing the appropriate eye protection while working around furnaces and metal forgings 1900 to 2100 degrees Fahrenheit.      b)  Hammer Department, on or about 6/1/18:  Employees are exposed to potentially injurious infrared light in that they were not wearing the appropriate eye protection while working around furnaces and metal forgings 1900 to 2100 degrees Fahrenheit.      c)  Ring Roll Department, on or about 6/1/18:  Employees are exposed to potentially injurious infrared light in that they were not wearing the appropriate eye protection while working around furnaces and metal forgings 1900 to 2100 degrees Fahrenheit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Jun 20, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Maintenance, on or about 6/1/18:  Edlund multi-drill press was used without a guard to prevent contact with the rotating chucks and tooling.    b)  Maintenance, on or about 6/1/18:  Oster Rapiduction threading machine used to thread 7-inch long bolts, was not equipped with a guard to prevent contact with rotating parts.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.304 G05

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 20, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a)  Near Press #2, on or about 6/1/18:  Path to ground from an operating pedestal fan was not permanent, continuous  and effective in that the ground pin was missing from the plug attachment.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

View Hammond & Irving INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343197729.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.