OSHA Inspection: PETERSON WELDING AND MACHINE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETERSON WELDING AND MACHINE LLC in P.O. BOX 101 6.5 MILE COPPER RIVER HWY, CORDOVA, AK 99574 (NAICS 336611). OSHA activity number 343199881.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Peterson Welding and Machine LLC — free Get an email when a new federal OSHA severe-injury report for Peterson Welding and Machine LLC is published. One employer, no account, unsubscribe in one click.
Site address
P.O. BOX 101 6.5 MILE COPPER RIVER HWY
City
CORDOVA
State
AK
ZIP
99574
Mailing
P.O. BOX 101 6.5 MILE COPPER RIVER HWY, CORDOVA, AK 99574
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
5
Ownership type
A

10 citations on file for this inspection.

1910.101 B

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $2,217 · Current $1,109 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  Bay One, on or about 31 May 2018 and times prior thereto; two compressed gas cylinders, one oxygen and one acetylene, that were not in use, were not secured to prevent damage in accordance as required by Compressed Gas Association Pamphlet P-1-1965 . This condition exposed employees to injury from fire and explosion hazard.
Recent events (2)
  • — I (S) $1108.5
  • — Z (S) $2217

1910.212 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $3,880 · Current $1,940 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  Shop Bays Two and Three; on or about 31 May 2018 and times prior thereto; two instances were noted where mechanical machines did not have barrier guards installed.        a. Bay Two, a Masteel Shear; model 12250, serial number 0158, did not have a barrier guard installed to prevent access behind the machine during operations. Miscellaneous items were stored behind the machine.             b. Bay Three, a Masteel Shear; model 12250, serial number 0244, did not have a barrier guard installed to prevent access behind the machine during operations. Miscellaneous items were stored behind the machine.    This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3880

1910.219 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.  Bay Three, on or about 31 May 2018 and times prior thereto; a shop made hydraulically driven blade roller did not have a protective guard over the sprocket. This condition exposed employees to a caught in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C01 II A

Serious Gravity 1 2 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $1,663 · Current $832 Reduced
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) on portable abrasive wheel(s) were not mounted so as to maintain proper alignment with the wheel.  Bay Two, on or about 31 May 2018 and times prior thereto, two instances were noted where angle grinders did not have the protective guards installed.       a. A Bosch angle grinder, model GWS 10-45P, serial number 610008261 did not have the protective guard installed.       b. A Dewalt angle grinder, model DWE402, serial number unknown did not have the protective guard installed.  This condition exposed employees to a caught in hazard.
Recent events (2)
  • — I (S) $831.5
  • — Z (S) $1663

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $1,663 · Current $832 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  Bay Two, center stanchion; on or about 31 May 2018 and times prior thereto, a knockout plug was missing on the right hand side of an energized electrical outlet. This condition exposed employees to an electrical and fire hazards.
Recent events (2)
  • — I (S) $831.5
  • — Z (S) $1663

1910.305 B02 I

Serious Gravity 1 2 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  Bay Three, outer wall, on or about 31 May 2018 and times prior thereto, two energized electrical outlet boxes did not have a cover plate installed. This condition exposed employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 3 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Shop bays, on or about 31 May 2018 and times prior thereto, three instances were noted where flexible cord sets were not visually inspected for damage:       a. Bay One, a orange 50-foot medium duty extension cord had damage to the outer protective jacket.            b. Bay One, a yellow 50-foot heavy duty extension cord had the outer protective insulation separated from the receptacle plug.       c. Bay Three, a orange medium duty extension cord had the outer protective insulation separated from the receptacle plug.  This condition exposed employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious 1 instance 5 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed.  Bay Three, on or about 31 May 2018 and times prior thereto; the emergency exit path was blocked. Boxes of miscellaneous items were stored in front of the doorway impeding the exit path. This condition exposed employees to a fire hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 3 instances 3 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  Bay One, on or about 31 May 2018 and times prior thereto; the employer did not ensure that portable fire extinguishers were mounted and readily available. This condition exposed employees to delays in exiting the building causing smoke inhalation and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 3 instances 5 exposed
Issued
Jun 11, 2018
Abate by
Jul 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly.  Throughout the facility, on or about 31 May 2018 and times prior thereto; Amerex ABC portable fire extinguishers were not inspected at least monthly. This exposed employees to delays in exiting the building causing smoke inhalation and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0