OSHA Inspection: OHIO VALLEY STAVE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OHIO VALLEY STAVE, INC. in 15447 U.S. 23, WAVERLY, OH 45690 (NAICS 321920). OSHA activity number 343208872.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ohio Valley Stave, INC. — free Get an email when a new federal OSHA severe-injury report for Ohio Valley Stave, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15447 U.S. 23
City
WAVERLY
State
OH
ZIP
45690
Mailing
18253 ST. RT. 73, MC DERMOTT, OH 45652
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
36
Ownership type
A

4 citations on file for this inspection.

1910.213 R04

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 31, 2018
Abate by
Oct 19, 2018
Penalty
Initial $9,959 · Current $3,984 Reduced
29 CFR 1910.213(r)(4): The mention of specific machines in paragraphs (a) thru (q) and this paragraph (r) of this section, inclusive, is not intended to exclude other woodworking machines from the requirement that suitable guards and exhaust hoods be provided to reduce to a minimum the hazard due to the point of operation of such machines.    On May 25, 2018 employees were exposed to struck-by hazards, in that the reclaim stave edger was not provided with a suitable guard, in that the employee could reach into the point of operation.
Recent events (2)
  • — I (S) $3983.6
  • — Z (S) $9959

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2018
Abate by
Oct 19, 2018
Penalty
Initial $9,959 · Current $7,967 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    On June 5, 2018 the employer did not conduct periodic inspections of the energy control procedure for the reclaim stave edger annually to ensure that the procedure and the requirements of this standard were being followed.
Recent events (2)
  • — I (S) $7967.2
  • — Z (S) $9959

1910.147 C04 I

Repeat Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2018
Abate by
Oct 19, 2018
Penalty
Initial $19,918 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     On May 25, 2018 procedures were not utilized for the control of potentially hazardous energy for the reclaim stave edger.    Ohio Valley Stave, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1296481, citation number 1, item number 1 and was affirmed as a final order on February 20, 2018, with respect to a workplace located at 15447 U.S. 23 Waverly, OH.
Recent events (2)
  • — I (R) $0
  • — Z (R) $19918

1910.147 C07 I A

Repeat Gravity 10 1 instance 3 exposed
Issued
Aug 31, 2018
Abate by
Oct 19, 2018
Penalty
Initial $19,918 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    On June 5, 2018 each authorized employee did not receive training for the methods and means necessary for energy isolation and control for the reclaim stave edger.    Ohio Valley Stave, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1296481, citation number 1, item number 2 and was affirmed as a final order on February 20, 2018, with respect to a workplace located at 15447 U.S. 23 Waverly, OH.
Recent events (2)
  • — I (R) $0
  • — Z (R) $19918

View Ohio Valley Stave, INC.'s full OSHA safety record →