WEST PITTSTON, PA —
OSHA Inspection: EDM AMERICAS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of EDM AMERICAS, INC. in 199 SOUTH ST., WEST PITTSTON, PA 18643 (NAICS 541512). OSHA activity number 343209623.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDM AMERICAS, INC.
- Site address
- 199 SOUTH ST.
- City
- WEST PITTSTON
- State
- PA
- ZIP
- 18643
- Mailing
- 10 E.D. PREATE DRIVE, MOOSIC, PA 18507
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541512
- Employees
- 20
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B01 I
- Issued
- Nov 26, 2018
- Abate by
- Dec 13, 2018
- Penalty
- Initial $8,315 · Current $6,652 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) Warehouse: Employees were not provided fall protection while operating the Crown SP 3000 series, Serial Number 1A257569 stockpicker to retrieve stored files from the upper levels of metal storage racks, exposing employees to fall hazards, observed on or about June 1, 2018. Abatement Certification Required
Recent events (2)
- — I (S) $6652
- — Z (S) $8315
1910.37 A03
- Issued
- Nov 26, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $8,315 · Current $6,652 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Warehouse (Section 800): The emergency exit #9 was blocked by a conveyor equipment exposing employees to fire hazards, as observed on or about June 27, 2018. b) Warehouse (Dock Area): The emergency exit door was blocked by a hand truck, plastic crates, and other materials, exposing employees to fire hazards, as observed on or about June 27, 2018. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $6652
- — Z (S) $8315
1910.37 B04
- Issued
- Nov 26, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Warehouse: The direction of travel to the exit or exit discharge routes was not conspicuous throughout the approximately 175,000 square feet warehouse, and there were no signs posted along the exit routes and exit access indicating the direction of travel to the exit routes, exposing employees to fire hazards, as observed on or about June 27, 2018. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Nov 26, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Warehouse (Section 600): The emergency door #6 had a broken Exit sign and it was not illuminated at all, exposing employees to fire hazards as observed on or about June 27, 2018. b) Warehouse (Section 800): The Exit sign in the upper level was broken and it was not illuminated, exposing employees to fire hazards, as observed on or about June 27, 2018. c) Warehouse (Section 800): The Exit sign located above emergency door #9 was not illuminated, exposing employees to fire hazards, as observed on or about June 27, 2018. d) Warehouse (Dock Area): The Exit sign located above the exit door was not illuminated, exposing employees to fire hazards, as observed on or about June 27, 2018. e) Warehouse (Dock Area): The Exit sign located above the exit discharge door was not illuminated, exposing employees to fire hazards, as observed on or about June 27, 2018. f) Microfilm Dept: Two Exit signs located above the front and back doors were not illuminated, exposing employees to fire hazards, as observed on or about June 27, 2018. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Nov 26, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $6,652 · Current $5,321 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Warehouse: Employees were given a Crown SP 3000 series stockpicker, a Crown orderpicker and pallet jacks to conduct document retrieval activities and the employer did not ensure each operator successfully completed formal instruction, practical training, and evaluation of the operator's performance in the workplace, observed on or about June 1, 2018. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $5321
- — Z (S) $6652
1910.178 L04 III
- Issued
- Nov 26, 2018
- Abate by
- Dec 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operators performance was not conducted at least once every 3 years: a) Workplace: The employer did not ensure employees operating the Crown SP 3000 series, serial number 1A257569 received refresher training once every three years, observed on or about June 1, 2018. ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
5(a)(1)
- Issued
- Nov 26, 2018
- Abate by
- Feb 28, 2019
- Penalty
- Initial $13,304 · Current $10,643 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) Warehouse: Employees stored and retrieved records from a Wireway Husky metal storage rack system throughout the warehouse which had damaged bottom columns and cross braces. Employees were exposed to struck-by and crushed-by hazards in the event of a metal storage rack system collapse, as observed on or about June 1, 2018. ABATEMENT CERTIFICATION AND DOCUMENTATION ARE REQUIRED FOR THIS VIOLATION. EDM Americas, Inc. was previously cited for a violation of the OSH ACT of 1970 Section (5)(a)(1), which was contained in OSHA inspection number 981063, citation number 1, item number 1 and was affirmed as a final order on November 3, 2014, with respect to a workplace located at 4th St./Pacific Ave., West Pittston, PA 18643.
Recent events (2)
- — I (R) $10643
- — Z (R) $13304
1910.28 B01 I
- Issued
- Nov 26, 2018
- Abate by
- Feb 28, 2019
- Penalty
- Initial $129,336 · Current $103,469 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) Warehouse: Employees conducted records management tasks from elevated platforms that had unprotected sides (Wireway Husky racking system) ranging from about 10 to 14 feet high from above lower level, which were not adequately equipped with a fall protection system. Employees were exposed to fall hazards as observed on or about June 1, 2018. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED FOR THIS VIOLATION. EDM Americas, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.23(c)(1), which was contained in OSHA inspection number 981063, citation number 1, item number 2 and was affirmed as a final order on November 3, 2014, with respect to a workplace located at 4th St./Pacific Ave., West Pittston, PA 18643.
Recent events (2)
- — I (R) $103469
- — Z (R) $129336
More inspections at EDM Americas, INC.
View EDM Americas, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 541512)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343209623.