O BRIEN, FL —
OSHA Inspection: SUWANNEE IRON WORKS & FENCE, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SUWANNEE IRON WORKS & FENCE, INC. in 22618 COUNTY ROAD 49, O BRIEN, FL 32071 (NAICS 332323). OSHA activity number 343214821.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUWANNEE IRON WORKS & FENCE, INC.
- Site address
- 22618 COUNTY ROAD 49
- City
- O BRIEN
- State
- FL
- ZIP
- 32071
- Mailing
- 22618 COUNTY ROAD 49, O BRIEN, FL 32071
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B04 III
- Issued
- Sep 7, 2018
- Penalty
- Initial $6,047 · Current $3,547 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On June 6, 2018, in the upper shop, full and empty oxygen cylinders were stored near full and empty fuel gas cylinders, exposing employees to a fire hazard.
Recent events (2)
- — I (S) $3547
- — Z (S) $6047
1910.303 B01
- Issued
- Sep 7, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $6,047 · Current $3,547 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees: a. On June 7, 2018, in the upper shop, a power cord was plugged into an outlet that had a broken cover, exposing employees to a 220 volts electrical hazard.
Recent events (2)
- — I (S) $3547
- — Z (S) $6047
1910.305 G02 III
- Issued
- Sep 7, 2018
- Abate by
- Sep 17, 2018
- Penalty
- Initial $284 · Current $284
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a. On June 7, 2018, in the upper shop, the power cord to the machine did not have strain relief, exposing the inner insulation. Suwannee Iron Works was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(2)(iii), which was contained in OSHA inspection number 1066308, citation number 1, item number 8 and was affirmed as a final order on November 30, 2015 with respect to a workplace located at 22618 CR 49, Obrien, Florida 32071.
Recent events (2)
- — I (R) $284
- — Z (R) $284
More inspections at Suwannee Iron Works & Fence, INC.
View Suwannee Iron Works & Fence, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343214821.