OSHA Inspection: SUWANNEE IRON WORKS & FENCE, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SUWANNEE IRON WORKS & FENCE, INC. in 22618 COUNTY ROAD 49, O BRIEN, FL 32071 (NAICS 332323). OSHA activity number 343214821.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Suwannee Iron Works & Fence, INC. — free Get an email when a new federal OSHA severe-injury report for Suwannee Iron Works & Fence, INC. is published. One employer, no account, unsubscribe in one click.
Site address
22618 COUNTY ROAD 49
City
O BRIEN
State
FL
ZIP
32071
Mailing
22618 COUNTY ROAD 49, O BRIEN, FL 32071
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 7, 2018
Penalty
Initial $6,047 · Current $3,547 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a. On June 6, 2018, in the upper shop, full and empty oxygen cylinders were stored near full and empty fuel gas cylinders, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $3547
  • — Z (S) $6047

1910.303 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 7, 2018
Abate by
Sep 17, 2018
Penalty
Initial $6,047 · Current $3,547 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees:    a. On June 7, 2018, in the upper shop, a power cord was plugged into an outlet that had a broken cover, exposing employees to a 220 volts electrical hazard.
Recent events (2)
  • — I (S) $3547
  • — Z (S) $6047

1910.305 G02 III

Repeat 1 instance 4 exposed
Issued
Sep 7, 2018
Abate by
Sep 17, 2018
Penalty
Initial $284 · Current $284
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a. On June 7, 2018, in the upper shop, the power cord to the machine did not have strain relief, exposing the inner insulation.  Suwannee Iron Works  was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.305(g)(2)(iii), which was contained in OSHA inspection number 1066308, citation number 1, item number 8 and was affirmed as a final order on November 30, 2015 with respect to a workplace located at 22618 CR 49, Obrien, Florida 32071.
Recent events (2)
  • — I (R) $284
  • — Z (R) $284

View Suwannee Iron Works & Fence, INC.'s full OSHA safety record →