OSHA Inspection: AVLON INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AVLON INDUSTRIES, INC. in 1999 N. 15TH AVE., MELROSE PARK, IL 60160 (NAICS 325620). OSHA activity number 343226643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avlon Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Avlon Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1999 N. 15TH AVE.
City
MELROSE PARK
State
IL
ZIP
60160
Mailing
1999 N. 15TH AVE., MELROSE PARK, IL 60161
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325620
Employees
140
Ownership type
A

4 citations on file for this inspection.

1910.25 B03

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 4, 2018
Abate by
Dec 31, 2018
Penalty
Initial $3,742 · Current $2,619 Reduced
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings:    a) Compounding Room- On June 13, 2018, the employer did not ensure that the steps on the stairs had uniform riser heights on the staircase closest to the wall in the Compounding Room. The riser height ranged between 8 inches to 11 inches.
Recent events (2)
  • — I (S) $2619.4
  • — Z (S) $3742

1910.25 C02

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 4, 2018
Abate by
Dec 31, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.25(c)(2): 29 CFR 1910.25(c)(2): The employer did not ensure standard stairs have a maximum riser height of 9.5 inches (24 cm).  a) Compounding Room- On June 13, 2018, the employer did not ensure that the steps on the stairs had a maximum riser height of 9.5 inches (24 cm).The riser heights on the first step of the staircase closest to the wall in the Compounding Room was 11 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A02

Other-than-serious 1 instance 3 exposed
Issued
Dec 4, 2018
Penalty
Initial $700 · Current $490 Reduced
29 CFR 1910.22(a)(2): The floor of each work area was not maintained in a clean and, to the extent feasible, dry condition.    a) Compounding Room- On June 13, 2018, the employer did not ensure that the floor was maintained, to the extent feasible, in a dry condition. The floor was slippery from the residual water and soap after the tanks had been flushed.
Recent events (2)
  • — I (O) $490
  • — Z (O) $700

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Dec 4, 2018
Penalty
Initial $700 · Current $490 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Batching and Filling Department On June 13, 2018, the employer did not ensure that all electrical equipment was installed and used in accordance with its listing and labeling. A power strip was used to supply power to portable conveyors and other equipment.
Recent events (2)
  • — I (O) $490
  • — Z (O) $700

View Avlon Industries, INC.'s full OSHA safety record →