Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RCD GROUP INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RCD GROUP INC. in MARTIN TOWER 1117 8TH AVE., BETHLEHEM, PA 18018 (NAICS 238910). OSHA activity number 343248563.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RCD Group INC. — free Get an email when a new federal OSHA severe-injury report for RCD Group INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RCD GROUP INC.
Site address
MARTIN TOWER 1117 8TH AVE.
City
BETHLEHEM
State
PA
ZIP
18018
Mailing
3477 CORPORATE PARKWAY SUITE 100, CENTER VALLEY, PA 18034
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
85
Ownership type
A

2 citations on file for this inspection.

1926.451 F03

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 19, 2018
Penalty
Initial $2,523 · Current $2,523
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  a) Martin Tower, basement - On or about June 18, 2018, a mobile scaffold with damaged cross brace retaining clips was not inspected by a competent person before each shift.
Recent events (1)
  • — Z (S) $2523

1926.451 F04

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 19, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired:  a) Martin Tower, basement - On or about June 19, 2018, a mobile scaffold with damaged cross brace retaining clips was used by employees, but had not been repaired or identified as being removed from service.
Recent events (1)
  • — Z (S) $0

View RCD Group INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343248563.