Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROGRESSIVE BUILDERS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROGRESSIVE BUILDERS, LLC. in 1009 17TH STREET, NE, WASHINGTON, DC 20002 (NAICS 236118). OSHA activity number 343250049.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Progressive Builders, LLC. — free Get an email when a new federal OSHA severe-injury report for Progressive Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1009 17TH STREET, NE
City
WASHINGTON
State
DC
ZIP
20002
Mailing
3560 13TH STREET, NW, WASHINGTON, DC 20010
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.1052 C01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 12, 2018
Abate by
Jul 18, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) First Floor Stairway - Employees were using a stairway that measured 35 inches wide, with 18 risers, with a total rise of 10 feet, 2 inches and there was no handrail, on or about 06/22/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1663

1926.1052 C01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 12, 2018
Abate by
Jul 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) First Floor Stairway - Employees were using a stairway that measured 35 inches wide, with 18 risers, with a total rise of 10 feet, 2 inches and there was no stair rail, on or about 06/22/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 12, 2018
Abate by
Jul 18, 2018
Penalty
Initial $1,663 · Current $1,663
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Fourth Floor Balcony - An employee was standing on a 6 foot portable step ladder that was leaning against the wall in the folded position, while handing material to employees on the roof, on or about 06/22/2018.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $1663

1926.501 B13

Repeat Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2018
Abate by
Jul 18, 2018
Penalty
Initial $7,760 · Current $7,760
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Roof Section - Employees were installing a polyethylene cover on a flat roof that measured 30 feet by 40 feet and not protected from a 20 feet fall hazard, on or about 06/22/2018.  Progressive Builders, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1261260, Citation number 1, item number 2, and was affirmed as a final order on 12/04/2017, with respect to a workplace located at 302 16th Street, NE Washington DC 20007.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (R) $7760

View Progressive Builders, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343250049.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.