Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAVAL FACILITIES ENGINEERING COMMAND

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NAVAL FACILITIES ENGINEERING COMMAND in 400 MARSHALL RD. BLDG. X21, PEARL HARBOR, HI 96860 (NAICS 928110). OSHA activity number 343257440.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naval Facilities Engineering Command — free Get an email when a new federal OSHA severe-injury report for Naval Facilities Engineering Command is published. One employer, no account, unsubscribe in one click.
Site address
400 MARSHALL RD. BLDG. X21
City
PEARL HARBOR
State
HI
ZIP
96860
Mailing
400 MARSHALL RD. BLDG. 75, PEARL HARBOR, HI 96860
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
12
Ownership type
D

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 12 exposed
Issued
Jul 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Welding shop Building X21, South end: The powered clamp which was part of a vertical tilt frame band saw was not guarded at the point of operation, exposing employees to caught-in hazards.
Recent events (1)
  • — Z (S) $0

1910.304 B03 II C 3

Serious Gravity 5 1 instance 12 exposed
Issued
Jul 16, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective was being and not repaired;  Welding shop Building X21, South end: A portable shop fan power cord was missing the ground pin, exposing workers to electrical hazards.