Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KONECRANES, INC.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of KONECRANES, INC. in 4243 GATEWAY DRIVE, SHEBOYGAN, WI 53081 (NAICS 811310). OSHA activity number 343259446.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Konecranes, INC. — free Get an email when a new federal OSHA severe-injury report for Konecranes, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KONECRANES, INC.
Site address
4243 GATEWAY DRIVE
City
SHEBOYGAN
State
WI
ZIP
53081
Mailing
3101 E. ENTERPRISE AVE., APPLETON, WI 54913
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
37
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Nov 8, 2018
Abate by
Dec 10, 2018
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section:  At a worksite located at 4243 Gateway Drive, Sheboygan, WI 53081; the employer did not develop or document machine specific energy control procedures for the control of potentially hazardous energy when Field Service Technicians were conducting lockout/tagout (LOTO) of the center overhead crane in the 3500 Ton Department. The Field Service Technicians were required to isolate the center overhead crane from electrical power as well as install rail stop mechanisms to isolate the crane from coming into contact with the powered east and west overhead cranes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12934

1910.179 L02 I E

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Nov 8, 2018
Abate by
Dec 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.179(l)(2)(i)(e):  Where other cranes are in operation on the same runway, rail stops or other suitable means shall be provided to prevent interference with the idle crane:  At a worksite located at 4243 Gateway Drive, Sheboygan, WI 53081; the employer did not ensure rail stops or other suitable means were provided to protect the center overhead crane in the 3500 Ton department from being contacted by another crane on the same runway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 II

Other-than-serious 1 instance 5 exposed
Issued
Nov 8, 2018
Abate by
Dec 31, 2018
Penalty
Initial $6,097 · Current $6,097

Hazardous substances 026004901591

29 CFR 1910.1200(h)(3)(ii):  Employee training shall include at least the physical, health, simple asphyxiation, combustible dust, and pyrophoric gas hazards, as well as hazards not otherwise classified, of the chemicals in the work area:    At a worksite located at 4243 Gateway Drive, Sheboygan, WI 53081; the employer did not provide training to employees on the health hazards of cadmium and inorganic arsenic. Employees were working in areas where residue from die casting process was present on equipment and surfaces throughout the department. The residue contained cadmium and inorganic arsenic.
Recent events (2)
  • — I (O) $6097
  • — Z (S) $6097

1910.132 D02

Deleted Other-than-serious 1 instance 5 exposed
Issued
Nov 8, 2018
Abate by
Dec 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2):  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment:  At a worksite located at 4243 Gateway Drive, Sheboygan, WI 53081; the employer did not certify that a workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person certifying that the evaluation had been performed; or the date(s) of the hazard assessment. Employees were exposed to hazardous chemicals contained in residue located on the ceiling and rafters of the 3500 Ton department when accessing the center overhead crane.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Konecranes, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343259446.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.