Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NCI GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NCI GROUP, INC. in 4310 INDUSTRIAL ACCESS ROAD, DOUGLASVILLE, GA 30134 (NAICS 332321). OSHA activity number 343269775.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NCI Group, INC. — free Get an email when a new federal OSHA severe-injury report for NCI Group, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NCI GROUP, INC.
Site address
4310 INDUSTRIAL ACCESS ROAD
City
DOUGLASVILLE
State
GA
ZIP
30134
Mailing
10943 NORTH SAM HOUSTON PARKWAY WEST, HOUSTON, TX 77064
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
97
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2018
Abate by
Dec 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gasses in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks was not in accordance with Compressed Gas Association Pamphlet P-1-1965:   a) Maintenance Building - Cylinder Storage Area: On or before June 5, 2018, and at times prior, the employer exposed employees to struck-by hazards, in that the employer did not ensure that the Acetylene storage cylinders were chained as required.
Recent events (1)
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 10 exposed
Issued
Nov 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  a) Building A: On or about June 5, 2018, and at times prior, the employer exposed employees to fire hazards because an A, B, C portable fire extinguisher (model # unknown, S/N unknown) was placed on floor and not mounted as required.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 instances 3 exposed
Issued
Nov 30, 2018
Abate by
Dec 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  a) Production Area - Building C: On or about June 5, 2018, and at times prior, the employer exposed employees to fire hazards because of an UL 15A 125V ac, relocatable power tap and extension cord were daisy chained and installed for use with a Dewalt chop saw (model #unknown).  b) Production Area - Building C: On or about June 5, 2018, and at times prior, the employer exposed employees to fire hazards because of an UL 15A 125V ac, relocatable power tap (Model # 77000) and extension cord were daisy chained and installed for use with an industrial fan (model #unknown).
Recent events (1)
  • — Z (O) $0

1910.304 F01 IV

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2018
Abate by
Dec 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Over-current devices were not readily accessible to each employee or authorized building management personnel.  a) Maintenance Building - On or about June 5, 2018, and at times prior, the employer exposed employees to shock hazards, in that the employer did not ensure that an electrical panel and a 208 V shut down switch were not blocked as required.  Tool boxes and other debris were placed approximately 9"-12" in front of an electrical panel and an electrical shut off.
Recent events (1)
  • — Z (O) $0

1910.1200 F05 I

Other-than-serious 1 instance 2 exposed
Issued
Nov 30, 2018
Abate by
Dec 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  a) Maintenance Building  Flammable Cabinet: On or about June 5, 2018, and at times prior, the employer exposed employees to irritation to eyes and skin hazards causing serious injury and impairment, in that the proper label with the identity was not legible on a container that contained anti-seize.
Recent events (1)
  • — Z (O) $0

View NCI Group, INC.'s full OSHA safety record →