MASSILLON, OH —
OSHA Inspection: FRESH MARK INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FRESH MARK INC. in 1888 SOUTHWAY ST. S.W., MASSILLON, OH 44646 (NAICS 311612). OSHA activity number 343271128.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRESH MARK INC.
- Site address
- 1888 SOUTHWAY ST. S.W.
- City
- MASSILLON
- State
- OH
- ZIP
- 44646
- Mailing
- P.O. BOX 571, MASSILLON, OH 44648
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 850
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Oct 3, 2018
- Abate by
- Oct 24, 2018
- Penalty
- Initial $12,934 · Current $11,374 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about July 2, 2018, employees were exposed to machine hazards associated with moving parts, in-going nip points, and thermal hazards during a maintenance servicing task. The #2 multi-vac raw bacon slicing and packaging machine at line 16 had a jam of film packaging material at the heat sealing die box. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect and the pneumatic valve [per the 1910.147(d)(4) requirements]. Employees were using small magnets (part 5463101003) placed on reed switch dual channel interlocking safety devices (part #103778984) to override and bypass the safety devices during the servicing task. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards. prepare for shutdown [(d)(1)]; - Ensure authorized employee has knowledge of the type, magnitude, the hazard, and the method or means to control the energy; shutdown the machine or equipment [(d)(2)]; machine isolation [(d)(3)]; Physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)]; Affix a lockout or tagout device to each energy isolating device; dissipation of residual energy [(d)(5)(i)]; relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; verification of isolation [(d)(6)]; verify that isolation and deenergization of the machine or equipment has been accomplished;
Recent events (3)
- — F (S) $11374
- — C (S) $12934
- — Z (S) $12934
More inspections at Fresh Mark INC.
View Fresh Mark INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343271128.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.