HENDERSON, CO —
OSHA Inspection: FUENTES ROOFING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FUENTES ROOFING LLC in 11498 MACON STREET, HENDERSON, CO 80640 (NAICS 238160). OSHA activity number 343274577.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUENTES ROOFING LLC
- Site address
- 11498 MACON STREET
- City
- HENDERSON
- State
- CO
- ZIP
- 80640
- Mailing
- 16075 E 16TH AVE, AURORA, CO 80011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Jul 6, 2018
- Abate by
- Aug 1, 2018
- Penalty
- Initial $4,435 · Current $2,600 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Fuentes Roofing LLC located at 11498 Macon Street, Henderson, CO 80640: On and preceding 7/3/2018, the employer did not ensure that employees engaged in residential roofing activities 6 feet or more above lower levels were protected by guardrail systems, safety net systems, or personal fall arrest systems. Four employees were removing shingles from the roof of a ranch-style residential home without the use of fall protection. The exposed employees to falls from height. Fuentes Roofing LLC was previously cited for a violation of is occupational safety and health standard or its equivalent 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1187722, citation number 1, Item 2, issued January 11, 2017 and became a final order on January 26, 2017, with respect to a workplace located at 4831 Bailey Place, Colorado Springs, CO 80911.
Recent events (2)
- — I (R) $2600
- — Z (R) $4435
More inspections at Fuentes Roofing LLC
View Fuentes Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343274577.