Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELLAK COLOR CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BELLAK COLOR CORPORATION in 9730 NW 25TH ST, DORAL, FL 33172 (NAICS 323111). OSHA activity number 343276994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bellak Color Corporation — free Get an email when a new federal OSHA severe-injury report for Bellak Color Corporation is published. One employer, no account, unsubscribe in one click.
Site address
9730 NW 25TH ST
City
DORAL
State
FL
ZIP
33172
Mailing
P.O. BOX 227656, MIAMI, FL 33222
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
38
Ownership type
A

7 citations on file for this inspection.

1910.28 B03 II

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 23, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.28(b)(3)(ii): Each employee was not protected from tripping into or stepping into or through any hole that was less than 4 feet (1.2 m) above a lower level by covers or guardrail systems:  On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.  An employee was exposed to a fall hazard while working in close proximity of a floor hole that lacked a cover.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 23, 2018
Abate by
Sep 18, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   On or about 7/5/2018, at the Press and Bindery Departments of Bellak Color Corporation, 9730 NW 25th St, Doral, FL. The employer did not establish an energy control program, resulting in the exposure of employees to a caught by hazard while performing servicing activities such as, but not limited to;  changing motors and/or pumps of a MBO, replacement of broken and/or missing parts of presses, cleaning and lubrication of bindery equipment, etc.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 23, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.  Employees were exposed to struck and caught by hazards while a powered industrial truck (i.e. Forklift, Nissan 50, No. KCH02A25PV) was operated without training and/or evaluation.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.212 A01

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 23, 2018
Penalty
Initial $3,298 · Current $1,979 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about 7/5/2018, at the Bindery department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.    a.  A guillotine cutter (i.e. Heidelberg, Model No. Not available) had its pedal unprotected against unintended operation, exposing employees being caught by the point of operation.    b.  Employees were exposed to a caught by hazard while walking and/or working in the proximity of a guillotine cutter (i.e. Heidelberg, Model No. Not available) that had rotating parts unguarded.
Recent events (2)
  • — I (S) $1978.8
  • — Z (S) $3298

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 23, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:   On or about 7/5/2018, at the Bindery Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.  A microwave oven (i.e. Whirlpool, No Model Available) was not provided with a continuous path to ground, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.305 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Aug 23, 2018
Abate by
Aug 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:   On or about 7/5/2018, at the Bindery Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.  A toggle switch was installed within an electrical junction box that had an unused opening which was not covered, exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 23, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about 7/5/2018, at the Press Department of Bellak Color Corporation, 9730 NW 25th St, Doral, FL.  A toggle switch was installed within an electrical junction box that lacked a coverplate, exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bellak Color Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343276994.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.