OSHA Inspection: AC EXTERIORS L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AC EXTERIORS L.L.C. in 5838 WHITECLIFF ROAD, ROCKFORD, IL 61109 (NAICS 238160). OSHA activity number 343280327.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AC Exteriors L.L.C. — free Get an email when a new federal OSHA severe-injury report for AC Exteriors L.L.C. is published. One employer, no account, unsubscribe in one click.
Establishment
AC EXTERIORS L.L.C.
Site address
5838 WHITECLIFF ROAD
City
ROCKFORD
State
IL
ZIP
61109
Mailing
717 SOUTH LAREDO CIRCLE, AURORA, CO 80017
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 30, 2018
Abate by
Nov 14, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means.   a. On or about July 06, 2018, at the above referenced inspection site, employees were required to remove (tear off) roofing shingles around an energized residential electrical service drop. The employer failed to ensure that employees were protected from contacting or damaging covered 120V lines by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means. Employees were thereby exposed to electrical burns / shock.  There is no abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $3880

1926.501 B13

Serious Gravity 5 2 instances 6 exposed
Issued
Oct 30, 2018
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system.  a. On or about July 06, 2018, at the above referenced inspection site, employees engaged in the removal and installation of roofing material at a residential property were exposed to falls of approximately eight (8) feet when the employer failed to ensure fall protection was utilized.    No abatement certification or documentation is required for this item.  b. On or about July 06, 2018, at the above referenced inspection site, employees were required to remove (tear off) roofing shingles around a skylight. Employees were exposed to falling through the skylight as no covers or fall protection was deployed in the area. Employees were thereby exposed to falls of approximately eight (8) feet to the interior of the home.   Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $2217

View AC Exteriors L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343280327.