WASHINGTON, DC —
OSHA Inspection: KERNS MASONRY INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KERNS MASONRY INC. in 4664 BROAD BRANCH NW, WASHINGTON, DC 20011 (NAICS 238140). OSHA activity number 343290847.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KERNS MASONRY INC.
- Site address
- 4664 BROAD BRANCH NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 2343 CONTEST LANE, HAYMARKET, VA 20169
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B05 I
- Issued
- Nov 14, 2018
- Abate by
- Nov 23, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: a) On or about July 9, 2018; front area of the residential building; the employee was observed walking on the platform of a scaffold system in which the platform ends extended three to four feet beyond the support frame exposing him to a 30-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3880
1926.451 C01 II
- Issued
- Nov 14, 2018
- Abate by
- Nov 23, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide. a) On or about July 9, 2018; front area of the residential building; the employee was observed working on the platform of a 4 tier scaffold system that was not secured to prevent from tipping exposing him to a 30-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3880
1926.451 E09 IV
- Issued
- Nov 14, 2018
- Abate by
- Nov 23, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. a) On or about July 9, 2018; front area of the residential building; the employee was observed using the scaffold system frame and cross-braces to access the fifth tier and fourth tier of the scaffold system exposing him to a 30-foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3880
1926.451 G02
- Issued
- Nov 14, 2018
- Abate by
- Nov 23, 2018
- Penalty
- Initial $3,880 · Current $3,880
General-duty citation text
29 CFR 1926.451(g)(2): The employer did not provide fall protection for employees erecting or dismantling supported scaffolds: a) On or about July 9, 2018; front area of the residential building; employees were observed adding/erecting another level on the scaffold without fall protection in place to protect them from falling 30-feet to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3880
More inspections at Kerns Masonry INC.
View Kerns Masonry INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343290847.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.