Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTEGRATED ILLUMINATION SYSTEMS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INTEGRATED ILLUMINATION SYSTEMS, INC. in 355 BANTAM LAKE RD, MORRIS, CT 06763 (NAICS 335122). OSHA activity number 343317046.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Integrated Illumination Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Integrated Illumination Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
355 BANTAM LAKE RD
City
MORRIS
State
CT
ZIP
06763
Mailing
355 BANTAM LAKE ROAD, MORRIS, CT 06763
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
165
Ownership type
A

2 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2018
Abate by
Dec 5, 2018
Penalty
Initial $6,652 · Current $3,326 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Assembly Area;  On or about 7/20/18, the employer did not have an eye wash/quick drenching facility available in the immediate work area where a corrosive glue, Dymax 7501-T-UR-SC, was being applied by employees.
Recent events (2)
  • — I (S) $3326
  • — Z (S) $6652

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2018
Abate by
Dec 5, 2018
Penalty
Initial $6,652 · Current $3,326 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Assembly Area;  On or about 7/20/18, the employer had not provided hazard communication/GHS training to employees working in the assembly area, using Dymax 7501-T-UR-SC glue. The contents of this material are considered corrosive, a sensitizer and may cause organ damage with repeated exposure.
Recent events (2)
  • — I (S) $3326
  • — Z (S) $6652

View Integrated Illumination Systems, INC.'s full OSHA safety record →