Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTEGRATED ILLUMINATION SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INTEGRATED ILLUMINATION SYSTEMS, INC. in 355 BANTAM LAKE ROAD, MORRIS, CT 06763 (NAICS 335122). OSHA activity number 343324133.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Integrated Illumination Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Integrated Illumination Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
355 BANTAM LAKE ROAD
City
MORRIS
State
CT
ZIP
06763
Mailing
355 BANTAM LAKE ROAD, MORRIS, CT 06763
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
134
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 25, 2018
Abate by
Nov 13, 2018
Penalty
Initial $6,652 · Current $4,656 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    Facility:  On, or about, July 20, 2018, the company had not developed and implemented a written lockout/tagout program that consisted of specific lockout procedures, lockout hardware and employee training.
Recent events (2)
  • — I (S) $4656.4
  • — Z (S) $6652

1910.212 A03 II

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 25, 2018
Penalty
Initial $8,315 · Current $5,821 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  On, or about, July 20, 2018, hazards created by machinery had not been adequately safeguarded:  A.  TM5Assembly Area:  Pinch point created at insertion area. B.  Machine Shop:  Point of operation on Kobalt sliding miter saw.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $8315

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 25, 2018
Penalty
Initial $4,240 · Current $2,968 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  SMT:  On, or about, July 20, 2018, three relocatable power taps were not used in accordance with listing/labeling contained in the UL Whitebook in that they were used series to provide power to a computer workstation.  Also, the relocatable power taps were energized through a green extension cord instead of being energized directly by permanently installed receptacles.
Recent events (2)
  • — I (S) $2968
  • — Z (S) $4240

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    SMT:  On, or about, July 20, 2018, a green extension cord was used to provide power to a computer workstation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.333 A

Serious Gravity 5 2 instances 8 exposed
Issued
Sep 25, 2018
Penalty
Initial $8,315 · Current $5,821 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    Final Assembly:  On, or about, July 20, 2018, employees were using Hi-Pot testing equipment to verify correct wiring and insulation on lighting components.  The testing was done on metal work tables with static dissipating mats. Electrical Safety Related Work Practices had not been developed and implemented in accordance with industry guidelines to reduce/eliminate the risk of electric shock to employees.
Recent events (2)
  • — I (S) $5820.5
  • — Z (S) $8315

1910.242 B

Other-than-serious 2 instances 5 exposed
Issued
Sep 25, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On, or about, July 20, 2018, in the following locations, compressed air nozzles used for cleaning were measured to be greater than 30 p.s.i., dead-ended:  A. TM5 Assembly Area. B.   Machine Shop: Bridgeport milling machine J256982.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Integrated Illumination Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343324133.