ALLENTOWN, PA —
OSHA Inspection: ACERO CONSTRUCTION, LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ACERO CONSTRUCTION, LLC in 825 N. WALL STREET, ALLENTOWN, PA 18109 (NAICS 238160). OSHA activity number 343317319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACERO CONSTRUCTION, LLC
- Site address
- 825 N. WALL STREET
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18109
- Mailing
- 17 ELM STREET, NEWARK, NJ 07102
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.28 A
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) 825 North Wall Street, Allentown, PA, Worksite, Roof - on or about July 20, 2018, an employee was operating a pneumatic powered coil nail gun without utilizing any means of eye protection.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1926.451 G01 I
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $3,880 · Current $2,179 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) 825 North Wall Street, Allentown, PA, Worksite - on or about July 20, 2018, employees were performing residential roofing work while standing on a ladder jack scaffold, approximately 13 feet, 8 inches above grade, without utilizing a personal fall arrest system.
Recent events (2)
- — I (S) $2178.6
- — Z (S) $3880
1926.451 A06
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not loaded in accordance with the design by a qualified person: a) 825 North Wall Street, Allentown, PA, Worksite - on or about July 20, 2018, employees were performing residential roofing work while standing on a ladder jack scaffold, approximately 13 feet, 8 inches above grade, without utilizing a personal fall arrest system.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $3,880 · Current $2,328 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) 825 North Wall Street, Allentown, PA, Worksite - on or about July 20, 2018, employees were performing residential roofing work, at a working height of approximately 23 feet above grade, without utilizing any means of fall protection.
Recent events (2)
- — I (S) $2328
- — Z (S) $3880
1926.1053 B01
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $2,772 · Current $1,663 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 825 North Wall Street, Allentown, PA, Worksite - on or about July 20, 2018, employees were using an extension ladder which was not extended at least three feet above the upper landing surface being accessed.
Recent events (2)
- — I (S) $1663.2
- — Z (S) $2772
1926.1053 B05 I
- Issued
- Jul 31, 2018
- Abate by
- Aug 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder: a) 825 North Wall Street, Allentown, PA, Worksite - on or about July 20, 2018, employees were using an extension ladder which was set at an angle in excess of one-quarter of its working length.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Acero Construction, LLC
View Acero Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343317319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.