OSHA Inspection: HAMILTON MASONRY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HAMILTON MASONRY LLC in 4301 BEMISS ROAD, VALDOSTA, GA 31605 (NAICS 238140). OSHA activity number 343318531.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hamilton Masonry LLC — free Get an email when a new federal OSHA severe-injury report for Hamilton Masonry LLC is published. One employer, no account, unsubscribe in one click.
Site address
4301 BEMISS ROAD
City
VALDOSTA
State
GA
ZIP
31605
Mailing
2186 WASHINGTON ROAD, HAMILTON, GA 31811
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 C03

Serious Gravity 10 3 instances 3 exposed
Issued
Sep 21, 2018
Abate by
Oct 18, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement:  a) Building C - On or about July 18, 2018 and prior to, employees working on a three tier tubular welded frame scaffold were exposed to struck-by hazards and fall hazards of up to approximately 17 feet, 8 inches in that the employer did not ensure that all of the frames were plumb to prevent swaying and displacement.
Recent events (1)
  • — Z (S) $3880

1926.451 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 21, 2018
Abate by
Oct 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  a) Building C - On or about July 18, 2018 and times prior to, employees working on the second level of a three tier tubular welded frame scaffold accessed scaffold platforms that were more than 2 feet above a point of access by climbing the ends of the scaffold, which were not equipped with suitable means of access, thus exposing employees to fall hazards of up to approximately 17 feet, 8 inches.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 21, 2018
Abate by
Oct 18, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a) Building C - On or about July 18, 2018 and times prior to, employees were working on a three tier tubular welded frame scaffold that did not have guardrail systems installed along all open sides and ends of platforms, thus exposing the employee to fall hazards of up to approximately 17 feet, 8 inches.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 21, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Second Floor Balcony, Building C - On or about July 18, 2018, an employee was permitted to walk/work at the edge of an open-sided balcony without being fall protected, thus exposing the employee to fall hazards of up to approximately 10 feet, 7.9 inches.
Recent events (1)
  • — Z (S) $3880