BARNESVILLE, PA —
OSHA Inspection: CORSICANA BEDDING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORSICANA BEDDING, INC. in 1214 MOREA ROAD, BARNESVILLE, PA 18214 (NAICS 337910). OSHA activity number 343321113.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORSICANA BEDDING, INC.
- Site address
- 1214 MOREA ROAD
- City
- BARNESVILLE
- State
- PA
- ZIP
- 18214
- Mailing
- 1214 MOREA ROAD, BARNESVILLE, PA 18214
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337910
- Employees
- 124
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 28, 2018
- Abate by
- Oct 18, 2018
- Penalty
- Initial $5,543 · Current $3,880 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) Emergency Exit #8, Springs Department, 1214 Morea Road, Barnesville, PA - Employees stored and retrieved materials from an orange metal storage rack system that had a bent and damaged cross brace exposing employees to struck-by and crushed-by hazards in the event of a metal storage rack system collapse, as observed on or about July 23, 2018. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $3880.1
- — Z (S) $5543
1910.303 B02
- Issued
- Sep 28, 2018
- Abate by
- Oct 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Wood Shop, 1214 Morea Road, Barnesville, PA - Employees used a Magic Chef Countertop Microwave Model MCD1611W plugged into an uninstalled flush receptacle that was not used or installed in accordance with its UL listing (RTRT) exposing employees to a contact with electrical current hazard, as observed on or about July 23, 2018. b) Matt Build and Tape Department, 1214 Morea Road, Barnesville, PA - Employees used a Sunbeam Countertop Microwave Model SGB8901 and a Dayton Commercial Pedestal-Mounted Air Circulator Model 1RWB5 that were plugged into a power strip that was not used or installed in accordance with its UL listing (XBYS) and "daisy chained" to an extension cord exposing employees to a contact with electrical current hazard, as observed on or about July 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Sep 28, 2018
- Abate by
- Oct 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Matt Build and Tape Department, 1214 Morea Road, Barnesville, PA - Employees used an extension cord attached to a power strip to energize a Countertop Microwave Model SGB8901 and a Dayton Commercial Pedestal-Mounted Air Circulator Model 1RWB5 and an extension cord to energize a TPI Portable Blower Model PB-36-B and an Intermec Commercial Printer Model PD42 for a period of time greater than six (6) months in lieu of fixed wiring exposing employees to a contact with electrical current hazard, on or about July 23, 2018. In accordance with 29 CFR 1903.19, abatement certification is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Corsicana Bedding, INC.
View Corsicana Bedding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343321113.